Skip to product information
1 of 6

electrical center b2c

TX6A Series 1/16 DIN PID Temperature Controller Replacement for Discontinued 48x48 pid controller

Regular price $47.00 USD
Regular price Sale price $47.00 USD
Sale Sold out
Shipping calculated at checkout.
Model NO. & Signal Output Type
Added ✓

autonics tc4s alternative,autonics tcn4s replacement 48x48,omron e5cc replacement 48x48,omron e5cn replacement same cutout,
shimaden sr1-8p replacement,delta dtb4848 alternative,west 6100+ replacement,
inoxtronic tr1 alternative 48x48,INKBIRD ITC-100RH alternative industrial,replacement for discontinued 48x48 pid controller

 

TX6A Series 1/16 DIN PID Temperature Controller DATA SHEET

 

YHKJ · TX6A 1/16 DIN PID Controller Model Code & Variants

2 Model Code Decoder

TX6 - A K 1 2 2 0 T — read left to right

Every TX6A part number is a literal description of the unit. Specifying — or re-ordering — a replacement is a matter of reading the code, not hunting through a catalogue.

Code position Value Meaning
TX6 Series TX6A intelligent PID controller family
A Case size A = 48 × 48 mm (1/16 DIN). B = 48 × 96, D = 72 × 72, E = 96 × 48 also available
K / A Input type K = universal thermocouple + RTD; A = 4-20 mA process input
1 / 2 / 4 / 5 Output 1 1 = relay · 2 = SSR drive · 3 = 4-20 mA · 4 = 0-10 V · 5 = SSR drive (alt. wiring)
2 Output 2 2 = second relay (dual output / dual alarm); 0 = not fitted
0 / 4 Option 0 = single alarm (AL1); 4 = dual alarm (AL1 + AL2)
T Communication T = RS-485 Modbus RTU; omitted = no comms
Example: TX6-AK220T = 48×48 mm case · universal thermocouple/RTD input · SSR-drive output 1 (12 V DC) · no output 2 · single alarm · RS-485 Modbus fitted. TX6-AA320 = same case, but a 4-20 mA process input with 4-20 mA retransmission output — for pressure, flow or level loops indicated in degrees.

">

YHKJ · TX6A 1/16 DIN PID ControllerAvailable Configurations

3 Available Configurations

Ten build-to-order part numbers
Part number Input Output 1 Output 2 Comms Alarms Typical use
TX6-AA320 4-20 mA process 4-20 mA — — AL1 Process loop, analog in and out
TX6-AK1220 TC / RTD universal Relay — — AL1 Base model, general purpose
TX6-AK1224 TC / RTD universal Relay Relay — AL1 + AL2 Dual alarm / two-stage heat-cool
TX6-AK120T TC / RTD universal Relay — RS-485 AL1 Relay + Modbus
TX6-AK1620 TC / RTD universal SSR 12 V — — AL1 SSR drive
TX6-AK220T TC / RTD universal SSR 12 V — RS-485 AL1 SSR + Modbus
TX6-AK2520 TC / RTD universal 0-10 V — — AL1 Analog voltage / SCR drive
TX6-AK420 TC / RTD universal 0-10 V — — AL1 PID, analog voltage
TX6-AK320 TC / RTD universal 4-20 mA — — AL1 Analog current retransmission
TX6-AK320T TC / RTD universal 4-20 mA — RS-485 AL1 Analog current + Modbus
Supply voltage is a separate order note. Standard build is 100-240 VAC, 50/60 Hz. For 24 VAC / 24 VDC control cabinets append -LV to the part number. Always state the supply when ordering — it is the single most common cause of a wrong-part delivery.
YHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice
3 / 18
YHKJ · TX6A 1/16 DIN PID ControllerParameter Reference

6 Parameter Quick Reference

The menu your commissioning tech actually needs

Press MODE to step between the user group and the engineering group; hold ◀◀ to shift digits, ▲/▼ to change the value, MODE again to store. The engineering group is password-protected — set LOCK before handover so a curious operator cannot retune a running loop.

Code Parameter Setting range Default Notes
P id Control mode 0 = ON/OFF · 1 = PID 1 Switches between simple differential control and full PID
H-c Action H = heat (reverse) · C = cool (direct) H Set to C for chillers, cooling towers and cooling zones
SV Setpoint Within the sensor range 0 Working temperature; lockable with the password function
P Proportional band 0.1-999.9 (°/°F) Auto Written by AT; smaller band = tighter but more active
I Integral time 0-3600 s Auto Removes steady-state offset; too short causes cycling
D Derivative time 0-1200 s Auto Anticipates rapid rise; leave at 0 on noisy PVs
FIL Input filter 0-100 Off Raises damping on the PV — use where VFD noise is present
AT Auto-tune ON / OFF OFF Runs one tuning cycle, then writes P / I / D automatically
AL1 / AL2 Alarm setpoints 1 & 2 Sensor range 0 Meaning depends on the selected alarm mode (17 modes)
AH1 / AH2 Alarm hysteresis 0.1-100.0 1.0 Prevents chatter at the trip point
SOFT Soft-start ramp 0-9999 Off Ramps SV up at power-up to protect elements
CYPT Timer program 4-digit code 0000 Sets timing mode and timer-end alarm behaviour
LOCK Password lock 0-9999 0 Locks the engineering group so operators cannot retune the loop
6 / 18
">
YHKJ · TX6A 1/16 DIN PID ControllerParameter Reference

6 Alarm Modes & Parameter Notes

7 / 18
YHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice
8 / 18
">
YHKJ · TX6A 1/16 DIN PID ControllerApplications

7 Where It Goes to Work

OEM machines, process skids, retrofit panels

1Packaging & sealing machinery

Sealing-jaw and shrink-tunnel temperature on form/fill/seal, band sealers and L-bar sealers. Relay output drives the contactor directly; AL2 trips the stack light on deviation.

2Plastics extrusion & injection

Barrel and die-zone control where SSR drive (AK1620 / AK220T) fires a 40 A SSR, and RS-485 feeds setpoints down from the machine PLC.

3Industrial ovens & heat treat

Batch ovens, cure ovens and small electric furnaces. Soft start and auto-tune hold ±1 °F on a 300 lb load; CYPT timer ends the soak and asserts alarm.

4Hot-runner & heating bands

Multi-zone hot-runner manifolds and band-heater barrels, one 48×48 controller per zone, 0-10 V output driving an SCR firing board on larger zones.

5Food & beverage process

Kettle, jacketed tank and proofing-room control with 100 Ω Pt RTD and 4-20 mA retransmission to the plant recorder.

6Incubators & agricultural

Hatchery and grow-room control, °F-native display, two-stage heat/cool from the AK1224 dual-relay version.

7OEM / machine-builder panels

Drop-in 45×45 mm cutout, 24 VAC/DC supply option and a published Modbus map make the TX6A a one-line BOM item for UL 508A control panels.

9 / 18
">
YHKJ · TX6A 1/16 DIN PID ControllerApplications

7 Sizing the Output to the Load

Match the output stage to the heater, not the other way round
Output type Practical load range Typical application
Integral relay (3 A) ≤ 1.5 kW @ 240 VAC resistive Small ovens, sealer jaws, solenoid and contactor pilot duty
SSR drive + external SSR 1.5 - 15 kW single phase Extrusion barrels, platen heaters, mid-size batch ovens
SSR drive + SCR firing board 15 kW+ or 3-phase Large ovens, heat-treat furnaces, multi-zone process skids
0-10 V / 4-20 mA analog Any, via external power controller Existing analog plant, SCR/thyristor packs, PLC setpoint cascading
Alarm modes (17): deviation / absolute / band, high & low, heater-current LBAT, sensor break and timer-end, with latching variants. AH1/AH2 set hysteresis; the alarm contact is rated 3 A @ 250 VAC resistive — pilot-duty a contactor or stack light, never switch a heater directly.
Rule of thumb for North American 240 VAC single-phase loads: ≤1.5 kW @240 VAC → relay; 1.5-15 kW → SSR-drive + heatsinked SSR (1.5× current); 15 kW+ / 3-phase → SCR firing board. Inductive loads derate the relay to ~50%.
YHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice
10 / 18
">
YHKJ · TX6A 1/16 DIN PID ControllerReplacement Guide

8 Drop-In Replacement Guide

Same 45×45 mm cutout — swap the instrument, not the panel

Most TX6A orders are replacements. Every controller below shares the 45 × 45 mm panel cutout, so the mechanical changeover is a screwdriver job. The electrical check is three items: supply voltage, sensor type, and output device.

Replacing Cutout What to check on changeover
Autonics TC4S / TCN4S 45×45 mm Same cutout, same terminal order (power 1-2, input 3-4, OUT1 5-6, OUT2 7-8). Swap the bezel, re-enter the sensor type, run auto-tune.
Omron E5CC / E5CN 45×45 mm Match supply voltage on the ordering code — 100-240 VAC standard, or -LV for the 24 VAC/DC cabinet. Reuse the existing SSR; the 12 V DC drive is compatible.
Delta DTB4848 45×45 mm TX6-AK1220 / AK1224 cover the RR dual-relay variants; AK1620 covers the SR relay-plus-SSR build.
Shimaden SR1 / SR3 45×45 mm Sensor type and alarm mode are re-selected in one menu pass; CYPT replaces the built-in timer function.
West 6100 / Cal 9400 45×45 mm Note the West 6100 uses a deeper case — check 75 mm behind-panel clearance before ordering.
REX-C100 / generic 48×48 45×45 mm Upgrade path for low-cost controllers: adds universal input, dual alarm, timer and Modbus in the same hole.

Changeover procedure

  • De-energise and lock out. Photograph the rear terminal strip before removing a single wire.
  • Record the old setup. Sensor type, SV, alarm setpoints, output action (heat/cool), and any tuned P/I/D.
  • Transfer the wiring in terminal order: 1-2 supply · 3-4 sensor input · 5-6 OUT1 · 7-8 OUT2 · A-B RS-485.
  • Set the input type and the °F/°C scale before applying power — a wrong sensor type reads as a wild PV, not as an error.
  • Run auto-tune once with the real load installed and the door closed. Expect one overshoot cycle; the controller then writes P, I and D itself.
  • Verify the alarm path by forcing a deviation, then set LOCK and file the parameter printout with the machine records.
YHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice
11 / 18
">
YHKJ · TX6A 1/16 DIN PID ControllerFAQ

11 Frequently Asked Questions

The questions our application engineers answer every week

QWill the TX6A fit the hole left by my Autonics TC4S?

Yes. Both use a 45 × 45 mm (1.77 × 1.77 in) panel cutout and a 48 × 48 mm bezel. Reuse the existing bracket and gasket; the rear terminals follow the same power / input / output order, so rewiring is a like-for-like transfer.

QIs the display in Fahrenheit?

°F is the default on North American shipments; switch to °C in the user menu at any time. The °F/°C LED on the faceplate shows which scale is active.

QWhich output do I order for a solid-state relay?

Order any code-2 or code-5 model — TX6-AK1620 (no comms) or TX6-AK220T (RS-485). Both deliver a 12 V DC pulse at ≈ 20 mA, which drives any standard panel-mount SSR with a DC input. Do not use the relay-output models to fire an SSR input directly without confirming the input current.

QMy heater is 10 kW — relay or SSR?

Above roughly 1.5 kW resistive at 240 VAC, use the SSR-drive version with a properly heatsinked SSR (or an SCR firing board for 3-phase). The integral 3 A relay is rated for pilot duty and small resistive loads only.

QDoes it carry UL listing?

The controller is built to UL 60730-1 / UL 60730-2-9 requirements. The standard North American offering is supplied as a UL Recognized Component (UR) for integration into UL 508A panels, with a panel-build support pack on request. Where a stand-alone UL Listed unit or cUL is contractually required, confirm the certificate status with your YHKJ sales contact before releasing the BOM — approval scope and SCCR data must be verified against the current UL Product iQ file, never assumed from the CE mark.

QCan I log data to my SCADA?

Yes, on any model with the T suffix. RS-485 Modbus RTU, address 1-100, 2400-38.4 kbaud. Register map ships as a PDF and as a CSV for direct import.

QWhat is the heater-break alarm, and do I need it?

The LBAT function watches for a heater that has gone open-circuit or an SSR that has failed short. For unattended ovens and any process where a cold part is scrap, specify the AK1224 dual-relay version and wire AL2 as the heater-fail output.

QHow do I stop the temperature overshooting on a small oven?

Run auto-tune (AT) once with the door closed and the real load in place, then raise FIL if the PV is noisy and add soft start if the elements are large. On very low thermal-mass loads, reduce the integral time rather than the proportional band.

QWhat is the lead time in North America?

Relay and SSR versions are the fastest-moving SKUs and are typically stocked state-side; analog and dual-alarm builds ship factory-direct. Confirm current stock and the incoterm applicable to your order (FOB / DDP) with your sales contact.

QWhat warranty and support do I get?

24 months from shipment against defects in materials and workmanship. Every order includes the full parameter list, wiring diagram and Modbus map; remote commissioning support is available during business hours ET.

YHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice

Care Instructions

Variant image

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)