YHKJ TX6-E 1/4 DIN PID Temperature Controller | 92×92 Cutout, 75mm Universal Thermocouple & RTD input · relay / SSR / 0-10 V / 4-20 mA output · RS-485 Modbus
Couldn't load pickup availability
1/4 din temperature controller ,92x92 cutout temperature controller ,quarter din temperature controller ,low depth panel temperature controller 96x96, large oven pid controller 1/4 din ,extruder barrel zone controller 96x96
shimaden sr93 replacement, sr93 alternative shallower depth 1/4 din, rkc ch902 replacement, pid temperature controller rkc cd901 alternative, 96x96 omron e5ac replacement, 1/4 din temperature controller autonics tk4l alternative, 96x96 pid delta dta9696r replacement, temperature controller fotek mt96 replacement, 1/4 din 1/4 din dial thermostat upgrade to pid analog, 96x96 controller replace with digital pid
The TX6-E is a panel-mounted PID temperature controller in a 96 × 96 mm case with a 92 × 92 mm cutout. It is the largest and most common panel format in the family, and unlike its TX6-D stablemate it is a genuine DIN 43700 size: 96 × 96 mm face, 92 × 92 mm cutout, one loop given the whole door. You choose it when one loop is worth a cabinet door of its own — a batch oven, a heat-treat furnace, an environmental chamber, a large extruder zone. The 1/4 DIN face carries the biggest characters in the TX6 range, readable from across a furnace floor, with PV / SV / MV on three separate lines so the operator sees not just the setpoint but whether the controller is actually firing. It is also where the depth fight matters most: the Japanese and Korean 1/4 DIN instruments this replaces sit 100 mm behind the panel, and the TX6-E sits 75 mm, so a shallow cabinet that would not close now closes. Same electronics as the TX6A / TX6B / TX6-E, one part-number logic, one parameter list, one Modbus map.
TX6E Product DATA SHEET Download
Available Configurations
All ten share the same 96 × 96 mm case, the same 92 × 92 mm cutout, the same universal input and the same 75 mm depth. They differ only in what they drive and whether they can talk.
| Part number | Input | Output 1 | Output 2 | Comms | Alarm | Typical use |
|---|---|---|---|---|---|---|
| TX6-EK1220 | TC / RTD universal | Relay 3 A | — | — | AL1 | General-purpose 1/4 DIN drop-in; direct contactor or pilot-duty switching |
| TX6-EK1224 | TC / RTD universal | Relay 3 A | Relay 3 A | — | AL1 + AL2 | Two-stage heat/cool, or one control stage plus a fully independent high-limit alarm |
| TX6-EK120T | TC / RTD universal | Relay 3 A | — | RS-485 Modbus | AL1 | Stand-alone machine reporting SV, PV and alarm state to the plant PLC or HMI |
| TX6-EK1620 | TC / RTD universal | SSR drive 12 V | — | — | AL1 | SSR + heatsink firing, zero-cross switching, silent and long-life |
| TX6-EK220T | TC / RTD universal | SSR drive 12 V | — | RS-485 Modbus | AL1 | Multi-zone networked ovens and extrusion barrels under PLC supervision |
| TX6-EK420 | TC / RTD universal | 0-10 V DC | — | — | AL1 | Analog setpoint input or SCR firing-board drive on an existing 0-10 V plant |
| TX6-EK1520 | TC / RTD universal | Relay 3 A | 0-10 V DC | — | AL1 | Relay for the contactor stage with analog retransmission to a recorder or second controller |
| TX6-EK320 | TC / RTD universal | 4-20 mA | — | — | AL1 | Long-run analog retransmission to a PLC analog input or chart recorder |
| TX6-EK320T | TC / RTD universal | 4-20 mA | — | RS-485 Modbus | AL1 | Full traceability — analog loop plus Modbus supervisory on one part number |
| TX6-EA320 | 4-20 mA (process) | 4-20 mA | — | — | AL1 | Pressure, flow or level loop indicated and controlled in engineering units |
TX6-EK1224 (relay + relay) gives you a real second stage or a fully independent high-limit alarm. TX6-EK1520 (relay + 0-10 V) gives you a contactor stage with analog retransmission. Every other code is single-output — if your circuit needs two, do not try to parallel the terminals.-LV to the part code and state it explicitly on the PO — a 24 V unit ordered without the suffix arrives as 120/240 V.General Specifications
| Item | Specification |
|---|---|
| Panel format | 96 × 96 mm (3.78 × 3.78 in) — 1/4 DIN, IEC / DIN 43700 |
| Panel cutout | 92 × 92 mm (3.622 × 3.622 in), + tolerance TBC — verify against the factory dimensional drawing |
| Case depth | 75 mm (2.95 in) behind panel; overall 96 × 96 × 75 mm; overall with terminal cover TBC |
| Mounting | Panel mount with two supplied clamping brackets; panel thickness TBC (typical 1.0-6.0 mm) |
| Display | 3-line LED: PV (white, upper), SV (green, middle), MV output % (orange, lower); 8-segment output bar; OC / AL1 / AL2 lamps |
| Display characters | PV / SV 4 digits, 12 mm (0.47 in) red/white-green LED — TBC against factory drawing |
| Keypad | MODE, shift, ▲, ▼ — sealed membrane front, IP rating TBC |
| Control | PID (with auto-tune) or ON/OFF; heat (reverse) or cool (direct); soft-start ramp; timer program |
| Sampling period | TBC — confirm before specifying for fast loops (reference: Autonics TK4L 50 ms, Delta DTA9696 0.5 s) |
| Accuracy | 0.5% |
| Power supply | 100-240 VAC, 50/60 Hz (standard) · 24 VAC/VDC optional (-LV); consumption TBC |
| Isolation / dielectric | TBC per factory test spec |
| Ambient | 0 to 50 °C (32 to 122 °F); 35-85 % RH non-condensing — TBC per factory spec |
| Minimum mounting pitch | TBC — side-by-side and vertical spacing on multi-zone panels; confirm against heat-rise data |
| Weight | 130G |
| Warranty | 24 months from shipment against defects in materials and workmanship |
Care Instructions
Care Instructions