TC4S Alternative | TX6A 1/16 DIN PID, 45x45 Cutout PID Controller

Regular price $47.00 USD
Regular price Sale price $47.00 USD
Sale Sold out
Shipping calculated at checkout.
Model NO. & Signal Output Type
Added ✓

TC4S, TCN4S & TK4S Alternative — Same 45×45 mm Cutout, Lower Landed Cost

The Autonics TC4S, TCN4S and TK4S are three of the most widely specified 1/16 DIN PID controllers in North America — and through distribution they typically land between US$95 and US$130 per unit, with lead times that stretch on the SSR and RS-485 variants. If you are fitting out a panel, retrofitting a machine, or simply replacing a failed unit on a Saturday, the TX6A gives you the same 45×45 mm cutout, the same universal thermocouple/RTD input list, and the same choice of relay, SSR-drive, 0–10 V and 4–20 mA outputs — at a fraction of the landed cost, with sample quantities available from one piece.

Why buyers switch

  • Same cutout, no panel rework. 45.0×45.0 mm (+0.6 mm) is the 1/16 DIN standard. The TX6A drops into an existing TC4S/TCN4S/TK4S aperture with no machining.
  • Same sensor list. J, K, T, R, S, B, E, N thermocouples plus Pt100/Cu50 RTD, and a dedicated 4–20 mA process-input variant (TX6-AA320) for pressure, flow and level loops.
  • Four output families in ten part numbers. Relay, SSR drive (12 VDC), 0–10 V and 4–20 mA, with single or dual alarm, and RS-485 Modbus RTU on the “T” suffixes.
  • Auto-tuning and digital filtering. AT identifies P/I/D on the real load; the FIL parameter damps noisy PV signals so the output does not chatter.
  • Sample-then-scale. One unit for evaluation, volume pricing from 10 pcs, shipped from the Yiwu, Zhejiang warehouse.

Specification cross-reference

Parameter Autonics TC4S / TCN4S / TK4S YHKJ TX6A Swap impact
Frame size 48 × 48 mm 48 × 48 mm Identical
Panel cutout 45 × 45 mm 45 × 45 mm (+0.6) No panel rework
Panel depth 64.5 mm TBC — confirm against drawing Publish the measured figure before launch
Display TCN4S: dual 4-digit PV/SV
TC4S/TK4S: single/dual by suffix
Dual 4-digit, PV red / SV green, MV bar Superset — no loss of readout
Thermocouple input K, J, T, R, S, B, E, N, C, L, U, PLII J, K, T, R, S, B, E, N Check C / L / U / PLII on the old spec before swapping
RTD input Pt100 Ω, Cu50Ω (DPt100 on -12 suffix) Pt100, Cu50 Compatible
Analog input 4–20 mA / 0–10 V by suffix 4–20 mA on TX6-AA320 Confirm loop power source
Control output Relay 250 VAC 3 A / SSR drive 12 VDC / 4–20 mA / 0–10 V / SCR trigger Relay / SSR 12 V / 0–10 V / 4–20 mA All four families covered
Control mode PID / ON-OFF, auto-tune PID / ON-OFF, AT, digital filter FIL Re-tune on install
Alarms Up to 3 (TC4S), 17 modes AL1 single, or AL1+AL2 dual (suffix 4) Map AL1/AL2 to the original functions
Communications RS-485 Modbus RTU RS-485 Modbus RTU, addr 1–247, 1.2–115.2 kbps (“T” suffix) Re-point the SCADA register map
Supply 100–240 VAC 50/60 Hz, optionally 12–24 VDC 100–240 VAC standard; 24 VAC/VDC as -LV Measure at the terminals before ordering
Approvals CE, RoHS; UL on request Designed to UL 60730-1 / 60730-2-9, supplied as UL Recognized Component for UL 508A panels; UL Listed TBC Do not claim UL Listed until the file number is issued

Autonics data from published TC4S / TCN4S / TK4S datasheets and North American distributor listings; TX6A data from the YHKJ TX6 series documentation. Suffix lettering and terminal positions must be re-checked against the nameplate of the unit being replaced.

Order the equivalent part number

If you are replacing… Order this TX6A Output / alarms
TC4S-14R / TC4S-24R (relay) TX6-AK1220 Relay, single alarm
TC4S with dual alarm TX6-AK1224 Relay, AL1 + AL2
TCN4S-14R with comms TX6-AK120T Relay + RS-485 Modbus
TC4S-14S / SSR-drive variant TX6-AK1620 SSR drive 12 VDC
TCN4S-24S with comms TX6-AK220T SSR drive + RS-485
TC4S 0–10 V analogue output TX6-AK2520 0–10 V + relay
TC4S 4–20 mA output TX6-AK320 / TX6-AK320T 4–20 mA, “T” adds RS-485
TC4S process-input (4–20 mA in) TX6-AA320 4–20 mA in / 4–20 mA out

 

Six steps to a clean swap

Photograph the nameplate
Record the full ordering code including every suffix letter — the same base model with a different suffix is a different output board.
Measure supply at the terminals
120 / 240 VAC on the North American site, or 24 VDC from the panel PSU. Order -LV if it is 24 V.
Confirm the sensor and its range
Thermocouple type, 2- vs 3-wire RTD, and whether the scale is °C or °F. TX6 is selectable °C/°F.
Measure free panel depth
From the inside of the cutout to the deepest obstruction. Compare with the TX6A drawing before ordering, not after.
Check whether the analogue output is actually used
Many legacy panels specify a 4–20 mA output that was never wired. If it is wired, match the output family exactly.
De-energise, rewire, re-tune
Terminal order is 1&2 supply / 3&4 input / 5&6 OUT1 / 7&8 OUT2 / A&B RS-485. Set SnPb, dP and Ar to match the old unit, then run auto-tune on the real load.
Rewiring is always required
No two brands share a terminal map. Even when the cutout is identical, the TX6A terminal order differs from the Autonics layout. Treat this as a re-termination job, not a pull-and-push swap, and re-run auto-tuning before returning the machine to production.

Frequently asked questions

Will the TX6A fit the hole left by a TC4S?

Yes. Both use the 1/16 DIN standard 45.0×45.0 mm cutout with +0.6 mm tolerance. No panel machining is needed. Confirm the free depth behind the panel against the TX6A outline drawing before ordering.

Do I need a different part number for a TCN4S vs a TC4S?

No — the cutout and depth are the same across TC4S, TCN4S and TK4S. Choose the TX6A part number by function instead: output type, number of alarms, and whether RS-485 is required.

Can I connect my existing K-type thermocouple directly?

Yes. Terminals 3 and 4 accept J, K, T, R, S, B, E and N thermocouples as well as Pt100/Cu50 RTDs. Set the input type parameter to match the sensor, and use the correct compensation if you are extending the thermocouple with non-TC cable.

Will my Modbus network still work?

The TX6A speaks Modbus RTU over RS-485 on the “T” suffixed models, address 1–247, 1.2–115.2 kbps. The protocol is standard, but the register map is not shared with Autonics — you will need to re-point the HMI or SCADA tags. Allow for that in the changeover window.

What about the 4–20 mA output my PLC reads?

Order the TX6-AK320 (or TX6-AK320T if you also need RS-485). If the loop is sourced by the controller, confirm the loop load budget against the PLC analogue input impedance before commissioning.