TC4S Alternative | TX6A 1/16 DIN PID, 45x45 Cutout PID Controller
Couldn't load pickup availability
TC4S, TCN4S & TK4S Alternative — Same 45×45 mm Cutout, Lower Landed Cost
The Autonics TC4S, TCN4S and TK4S are three of the most widely specified 1/16 DIN PID controllers in North America — and through distribution they typically land between US$95 and US$130 per unit, with lead times that stretch on the SSR and RS-485 variants. If you are fitting out a panel, retrofitting a machine, or simply replacing a failed unit on a Saturday, the TX6A gives you the same 45×45 mm cutout, the same universal thermocouple/RTD input list, and the same choice of relay, SSR-drive, 0–10 V and 4–20 mA outputs — at a fraction of the landed cost, with sample quantities available from one piece.
Why buyers switch
- Same cutout, no panel rework. 45.0×45.0 mm (+0.6 mm) is the 1/16 DIN standard. The TX6A drops into an existing TC4S/TCN4S/TK4S aperture with no machining.
- Same sensor list. J, K, T, R, S, B, E, N thermocouples plus Pt100/Cu50 RTD, and a dedicated 4–20 mA process-input variant (TX6-AA320) for pressure, flow and level loops.
- Four output families in ten part numbers. Relay, SSR drive (12 VDC), 0–10 V and 4–20 mA, with single or dual alarm, and RS-485 Modbus RTU on the “T” suffixes.
- Auto-tuning and digital filtering. AT identifies P/I/D on the real load; the FIL parameter damps noisy PV signals so the output does not chatter.
- Sample-then-scale. One unit for evaluation, volume pricing from 10 pcs, shipped from the Yiwu, Zhejiang warehouse.
Specification cross-reference
| Parameter | Autonics TC4S / TCN4S / TK4S | YHKJ TX6A | Swap impact |
|---|---|---|---|
| Frame size | 48 × 48 mm | 48 × 48 mm | Identical |
| Panel cutout | 45 × 45 mm | 45 × 45 mm (+0.6) | No panel rework |
| Panel depth | 64.5 mm | TBC — confirm against drawing | Publish the measured figure before launch |
| Display | TCN4S: dual 4-digit PV/SV TC4S/TK4S: single/dual by suffix |
Dual 4-digit, PV red / SV green, MV bar | Superset — no loss of readout |
| Thermocouple input | K, J, T, R, S, B, E, N, C, L, U, PLII | J, K, T, R, S, B, E, N | Check C / L / U / PLII on the old spec before swapping |
| RTD input | Pt100 Ω, Cu50Ω (DPt100 on -12 suffix) | Pt100, Cu50 | Compatible |
| Analog input | 4–20 mA / 0–10 V by suffix | 4–20 mA on TX6-AA320 | Confirm loop power source |
| Control output | Relay 250 VAC 3 A / SSR drive 12 VDC / 4–20 mA / 0–10 V / SCR trigger | Relay / SSR 12 V / 0–10 V / 4–20 mA | All four families covered |
| Control mode | PID / ON-OFF, auto-tune | PID / ON-OFF, AT, digital filter FIL | Re-tune on install |
| Alarms | Up to 3 (TC4S), 17 modes | AL1 single, or AL1+AL2 dual (suffix 4) | Map AL1/AL2 to the original functions |
| Communications | RS-485 Modbus RTU | RS-485 Modbus RTU, addr 1–247, 1.2–115.2 kbps (“T” suffix) | Re-point the SCADA register map |
| Supply | 100–240 VAC 50/60 Hz, optionally 12–24 VDC | 100–240 VAC standard; 24 VAC/VDC as -LV
|
Measure at the terminals before ordering |
| Approvals | CE, RoHS; UL on request | Designed to UL 60730-1 / 60730-2-9, supplied as UL Recognized Component for UL 508A panels; UL Listed TBC | Do not claim UL Listed until the file number is issued |
Autonics data from published TC4S / TCN4S / TK4S datasheets and North American distributor listings; TX6A data from the YHKJ TX6 series documentation. Suffix lettering and terminal positions must be re-checked against the nameplate of the unit being replaced.
Order the equivalent part number
| If you are replacing… | Order this TX6A | Output / alarms |
|---|---|---|
| TC4S-14R / TC4S-24R (relay) | TX6-AK1220 | Relay, single alarm |
| TC4S with dual alarm | TX6-AK1224 | Relay, AL1 + AL2 |
| TCN4S-14R with comms | TX6-AK120T | Relay + RS-485 Modbus |
| TC4S-14S / SSR-drive variant | TX6-AK1620 | SSR drive 12 VDC |
| TCN4S-24S with comms | TX6-AK220T | SSR drive + RS-485 |
| TC4S 0–10 V analogue output | TX6-AK2520 | 0–10 V + relay |
| TC4S 4–20 mA output | TX6-AK320 / TX6-AK320T | 4–20 mA, “T” adds RS-485 |
| TC4S process-input (4–20 mA in) | TX6-AA320 | 4–20 mA in / 4–20 mA out |
Six steps to a clean swap
-LV if it is 24 V.Frequently asked questions
Will the TX6A fit the hole left by a TC4S?
Yes. Both use the 1/16 DIN standard 45.0×45.0 mm cutout with +0.6 mm tolerance. No panel machining is needed. Confirm the free depth behind the panel against the TX6A outline drawing before ordering.
Do I need a different part number for a TCN4S vs a TC4S?
No — the cutout and depth are the same across TC4S, TCN4S and TK4S. Choose the TX6A part number by function instead: output type, number of alarms, and whether RS-485 is required.
Can I connect my existing K-type thermocouple directly?
Yes. Terminals 3 and 4 accept J, K, T, R, S, B, E and N thermocouples as well as Pt100/Cu50 RTDs. Set the input type parameter to match the sensor, and use the correct compensation if you are extending the thermocouple with non-TC cable.
Will my Modbus network still work?
The TX6A speaks Modbus RTU over RS-485 on the “T” suffixed models, address 1–247, 1.2–115.2 kbps. The protocol is standard, but the register map is not shared with Autonics — you will need to re-point the HMI or SCADA tags. Allow for that in the changeover window.
What about the 4–20 mA output my PLC reads?
Order the TX6-AK320 (or TX6-AK320T if you also need RS-485). If the loop is sourced by the controller, confirm the loop load budget against the PLC analogue input impedance before commissioning.
Is this a genuine Autonics part?
No. The TX6A is an independent product of YHKJ, sold by Electrical Center B2C. Autonics® is a trademark of its respective owner. The model names appear here only to identify equipment the TX6A is mechanically and functionally compatible with.