Schneider Electric GV2-PM Rotary Type Motor Circuit Breaker
Couldn't load pickup availability
motor circuit protector, GV2PM motor protector,Schneider GV2-PM, rotary motor circuit breaker, 0.16-32A, GV2 series, GVAE GVAN, motor protection
Schneider Electric GV2-pm Motor Circuit Breaker, 0.16-32A Adjustable Thermal Magnetic Overload & Short Circuit Protection, 3P 690VAC Motor Starter Protector
Product Description
- Dual Protection: Thermal magnetic design provides both overload and short-circuit protection for motors, preventing costly equipment damage.
- Wide Current Range: Available in adjustable ranges from 0.16A to 32A, suitable for various motor power ratings.
- Versatile Operation Styles: Choose between button-type (GV2-ME) and rotary-type (GV2-PM) for different control preferences.
- Expandable with Auxiliary Contacts: Compatible with GVAE series auxiliary contacts (1NO1NC/2NO) for status feedback and alarm integration.
- Reliable Schneider Quality: Certified with 3C and CE, ensuring safe and stable performance in industrial environments.
Specification
| Attribute | Parameter Details |
|---|---|
| Brand | Schneider Electric |
| Series | GV2-pm (rotary type)?? |
| Adjustable Current Ranges | 0.16-0.25A, 0.25-0.4A, 0.4-0.63A, 0.63-1A, 1-1.6A, 1.6-2.5A, 2.5-4A, 4-6.3A, 6-10A, 9-14A, 13-18A, 17-23A, 20-25A, 24-32A |
| Rated Voltage | 690VAC |
| Poles | 3P |
| Protection Type | Thermal magnetic (overload + short-circuit protection) |
| Auxiliary Contacts | GVAE11 (1NO1NC), GVAE20 (2NO) (front/side mount options) |
| Certifications | 3C, CE |
| Application | Motor protection, pumps, machine tools, conveyors, industrial control panels |
GV2-PM Full Model & Current Range Table (Rotary Knob MPCB)
| Full Model (MPN/MODEL NO.) | Adjustable Thermal Current Range | Operation Type | Terminal Type |
|---|---|---|---|
| GV2-PM01C | 0.1 ~ 0.16 A | Rotary Knob | Screw Clamp |
| GV2-PM02C | 0.16 ~ 0.25 A | Rotary Knob | Screw Clamp |
| GV2-PM03C | 0.25 ~ 0.40 A | Rotary Knob | Screw Clamp |
| GV2-PM04C | 0.40 ~ 0.63 A | Rotary Knob | Screw Clamp |
| GV2-PM05C | 0.63 ~ 1.00 A | Rotary Knob | Screw Clamp |
| GV2-PM06C | 1.00 ~ 1.60 A | Rotary Knob | Screw Clamp |
| GV2-PM07C | 1.60 ~ 2.50 A | Rotary Knob | Screw Clamp |
| GV2-PM08C | 2.50 ~ 4.00 A | Rotary Knob | Screw Clamp |
| GV2-PM10C | 4.00 ~ 6.30 A | Rotary Knob | Screw Clamp |
| GV2-PM14C | 6.00 ~ 10.0 A | Rotary Knob | Screw Clamp |
| GV2-PM16C | 9.00 ~ 14.0 A | Rotary Knob | Screw Clamp |
| GV2-PM21C | 13.0 ~ 18.0 A | Rotary Knob | Screw Clamp |
| GV2-PM22C | 17.0 ~ 23.0 A | Rotary Knob | Screw Clamp |
| GV2-PM32C | 20.0 ~ 32.0 A | Rotary Knob | Screw Clamp |
FAQs | Schneider GV2-PM Motor Circuit Breaker
Q1: What is the product model and function?
A1: GV2-PM series motor circuit breaker, 3P 690VAC thermal magnetic protector, provides overload, short circuit and phase failure protection for motors.
Q2: What is the adjustable current range?
A2: Adjustable from 0.16A up to 32A. Available current variants: 0.16-0.25A,0.25-0.4A,0.4-0.63A,0.63-1A,1.0-1.6A,1.6-2.5A,2.5-4.0A,4.0-6.3A,6.0-10A,13-18A,17-23A,20-25A,24-32A.
Q3: What operation types are available for GV2 series?
A3: Button type GV2-PM and rotary type GV2-ME for different operation preferences.
Q4: Can I add auxiliary contacts to this breaker?
A4: Yes. Compatible with GVAE front mount auxiliary contacts (GVA-E11, GVA-E20) and GVAN side mount auxiliary contacts (GVAN11, GVAN20), used for signal feedback and alarm output.
Q5: What does 1NO 1NC / 2NO mean?
A5: NO = Normally Open; NC = Normally Closed. 1NO1NC = one normally open + one normally closed contact; 2NO = two normally open contacts.
Q6: What is the rated voltage?
A6: Rated voltage 690VAC, 3 pole design.
Q7: What certifications does this motor protector have?
A7: CE and 3C certified, stable performance for industrial environments.
Q8: What are typical application scenarios?
A8: Pumps, machine tools, conveyors, industrial automation equipment, motor control cabinets.
Q9: What protection functions does it provide?
A9: Thermal overload protection, magnetic short-circuit protection, phase failure protection.
Q10: What is the difference between front mount and side mount auxiliary contacts?
A10: GVAE series: front mounting, installed on front face of circuit breaker. GVAN series: side mounting, installed on the side of the breaker.
Care Instructions