{"product_id":"tx6a-series-1-16-din-pid-temperature-controller-replacement-for-discontinued-48x48-pid-controller","title":"TX6A Series 1\/16 DIN PID Temperature Controller Replacement for Discontinued 48x48 pid controller","description":"\u003ch1\u003eautonics tc4s alternative,autonics tcn4s replacement 48x48,omron e5cc replacement 48x48,omron e5cn replacement same cutout,\u003cbr\u003eshimaden sr1-8p replacement,delta dtb4848 alternative,west 6100+ replacement,\u003cbr\u003einoxtronic tr1 alternative 48x48,INKBIRD ITC-100RH alternative industrial,replacement for discontinued 48x48 pid controller\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/YHKJ_TX6A_Temperature_Controller_NA_DetailPage_EN.pdf?v=1795069171\" title=\"autonics tc4s alternative,autonics tcn4s replacement 48x48,omron e5cc replacement 48x48,omron e5cn replacement same cutout, shimaden sr1-8p replacement,delta dtb4848 alternative,west 6100+ replacement, inoxtronic tr1 alternative 48x48,INKBIRD ITC-100RH alternative industrial,replacement for discontinued 48x48 pid controller\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eTX6A Series 1\/16 DIN PID Temperature Controller \u003cspan style=\"color: rgb(212, 115, 17);\"\u003eDATA SHEET\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller \u003c\/b\u003e\u003cspan\u003eModel Code \u0026amp; Variants\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e2\u003c\/span\u003e Model Code Decoder\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eTX6 - A K 1 2 2 0 T — read left to right\u003c\/div\u003e\n\u003cp\u003eEvery TX6A part number is a literal description of the unit. Specifying — or re-ordering — a replacement is a matter of reading the code, not hunting through a catalogue.\u003c\/p\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 16%;\"\u003e \u003ccol style=\"width: 16%;\"\u003e \u003ccol style=\"width: 68%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode position\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTX6A intelligent PID controller family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eCase size\u003c\/td\u003e\n\u003ctd\u003eA = 48 × 48 mm (1\/16 DIN). B = 48 × 96, D = 72 × 72, E = 96 × 48 also available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK \/ A\u003c\/td\u003e\n\u003ctd\u003eInput type\u003c\/td\u003e\n\u003ctd\u003eK = universal thermocouple + RTD; A = 4-20 mA process input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ 2 \/ 4 \/ 5\u003c\/td\u003e\n\u003ctd\u003eOutput 1\u003c\/td\u003e\n\u003ctd\u003e1 = relay · 2 = SSR drive · 3 = 4-20 mA · 4 = 0-10 V · 5 = SSR drive (alt. wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eOutput 2\u003c\/td\u003e\n\u003ctd\u003e2 = second relay (dual output \/ dual alarm); 0 = not fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 \/ 4\u003c\/td\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003e0 = single alarm (AL1); 4 = dual alarm (AL1 + AL2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eT = RS-485 Modbus RTU; omitted = no comms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"note\"\u003e\n\u003cb\u003eExample:\u003c\/b\u003e \u003ccode\u003eTX6-AK220T\u003c\/code\u003e = 48×48 mm case · universal thermocouple\/RTD input · SSR-drive output 1 (12 V DC) · no output 2 · single alarm · RS-485 Modbus fitted. \u003ccode\u003eTX6-AA320\u003c\/code\u003e = same case, but a 4-20 mA \u003ci\u003eprocess\u003c\/i\u003e input with 4-20 mA retransmission output — for pressure, flow or level loops indicated in degrees.\u003c\/div\u003e\n\u003cp\u003e\"\u0026gt;\u003c\/p\u003e\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eAvailable Configurations\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e3\u003c\/span\u003e Available Configurations\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eTen build-to-order part numbers\u003c\/div\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 17%;\"\u003e \u003ccol style=\"width: 15%;\"\u003e \u003ccol style=\"width: 11%;\"\u003e \u003ccol style=\"width: 9%;\"\u003e \u003ccol style=\"width: 10%;\"\u003e \u003ccol style=\"width: 11%;\"\u003e \u003ccol style=\"width: 27%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eOutput 1\u003c\/th\u003e\n\u003cth\u003eOutput 2\u003c\/th\u003e\n\u003cth\u003eComms\u003c\/th\u003e\n\u003cth\u003eAlarms\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AA320\u003c\/td\u003e\n\u003ctd\u003e4-20 mA process\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eProcess loop, analog in and out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK1220\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eBase model, general purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK1224\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1 + AL2\u003c\/td\u003e\n\u003ctd\u003eDual alarm \/ two-stage heat-cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK120T\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eRelay + Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK1620\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eSSR 12 V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eSSR drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK220T\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eSSR 12 V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eSSR + Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK2520\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e0-10 V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eAnalog voltage \/ SCR drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK420\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e0-10 V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003ePID, analog voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK320\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eAnalog current retransmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-AK320T\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eAnalog current + Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"callout\"\u003e\n\u003cb\u003eSupply voltage is a separate order note.\u003c\/b\u003e Standard build is 100-240 VAC, 50\/60 Hz. For 24 VAC \/ 24 VDC control cabinets append \u003ccode\u003e-LV\u003c\/code\u003e to the part number. Always state the supply when ordering — it is the single most common cause of a wrong-part delivery.\u003c\/div\u003e\n\u003cdiv class=\"pf\"\u003eYHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e3 \/ 18\u003c\/div\u003e\n\u003cdiv class=\"blk\"\u003e\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eParameter Reference\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e6\u003c\/span\u003e Parameter Quick Reference\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eThe menu your commissioning tech actually needs\u003c\/div\u003e\n\u003cp\u003ePress \u003ccode\u003eMODE\u003c\/code\u003e to step between the user group and the engineering group; hold \u003ccode\u003e◀◀\u003c\/code\u003e to shift digits, \u003ccode\u003e▲\u003c\/code\u003e\/\u003ccode\u003e▼\u003c\/code\u003e to change the value, \u003ccode\u003eMODE\u003c\/code\u003e again to store. The engineering group is password-protected — set \u003ccode\u003eLOCK\u003c\/code\u003e before handover so a curious operator cannot retune a running loop.\u003c\/p\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 10%;\"\u003e \u003ccol style=\"width: 22%;\"\u003e \u003ccol style=\"width: 22%;\"\u003e \u003ccol style=\"width: 10%;\"\u003e \u003ccol style=\"width: 36%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSetting range\u003c\/th\u003e\n\u003cth\u003eDefault\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP id\u003c\/td\u003e\n\u003ctd\u003eControl mode\u003c\/td\u003e\n\u003ctd\u003e0 = ON\/OFF · 1 = PID\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eSwitches between simple differential control and full PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH-c\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003ctd\u003eH = heat (reverse) · C = cool (direct)\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eSet to C for chillers, cooling towers and cooling zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSV\u003c\/td\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003eWithin the sensor range\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eWorking temperature; lockable with the password function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003eProportional band\u003c\/td\u003e\n\u003ctd\u003e0.1-999.9 (°\/°F)\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eWritten by AT; smaller band = tighter but more active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003ctd\u003eIntegral time\u003c\/td\u003e\n\u003ctd\u003e0-3600 s\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eRemoves steady-state offset; too short causes cycling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eDerivative time\u003c\/td\u003e\n\u003ctd\u003e0-1200 s\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAnticipates rapid rise; leave at 0 on noisy PVs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFIL\u003c\/td\u003e\n\u003ctd\u003eInput filter\u003c\/td\u003e\n\u003ctd\u003e0-100\u003c\/td\u003e\n\u003ctd\u003eOff\u003c\/td\u003e\n\u003ctd\u003eRaises damping on the PV — use where VFD noise is present\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAT\u003c\/td\u003e\n\u003ctd\u003eAuto-tune\u003c\/td\u003e\n\u003ctd\u003eON \/ OFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eRuns one tuning cycle, then writes P \/ I \/ D automatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAL1 \/ AL2\u003c\/td\u003e\n\u003ctd\u003eAlarm setpoints 1 \u0026amp; 2\u003c\/td\u003e\n\u003ctd\u003eSensor range\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eMeaning depends on the selected alarm mode (17 modes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAH1 \/ AH2\u003c\/td\u003e\n\u003ctd\u003eAlarm hysteresis\u003c\/td\u003e\n\u003ctd\u003e0.1-100.0\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003ePrevents chatter at the trip point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOFT\u003c\/td\u003e\n\u003ctd\u003eSoft-start ramp\u003c\/td\u003e\n\u003ctd\u003e0-9999\u003c\/td\u003e\n\u003ctd\u003eOff\u003c\/td\u003e\n\u003ctd\u003eRamps SV up at power-up to protect elements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCYPT\u003c\/td\u003e\n\u003ctd\u003eTimer program\u003c\/td\u003e\n\u003ctd\u003e4-digit code\u003c\/td\u003e\n\u003ctd\u003e0000\u003c\/td\u003e\n\u003ctd\u003eSets timing mode and timer-end alarm behaviour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLOCK\u003c\/td\u003e\n\u003ctd\u003ePassword lock\u003c\/td\u003e\n\u003ctd\u003e0-9999\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eLocks the engineering group so operators cannot retune the loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e6 \/ 18\u003c\/div\u003e\n\"\u0026gt;\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eParameter Reference\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e6\u003c\/span\u003e Alarm Modes \u0026amp; Parameter Notes\u003c\/h2\u003e\n\u003cdiv class=\"pn\"\u003e7 \/ 18\u003c\/div\u003e\n\u003cdiv class=\"pf\"\u003eYHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e8 \/ 18\u003c\/div\u003e\n\u003c!-- ============ P7 APPLICATIONS ============ --\u003e \"\u0026gt;\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eApplications\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e7\u003c\/span\u003e Where It Goes to Work\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eOEM machines, process skids, retrofit panels\u003c\/div\u003e\n\u003cdiv class=\"cards\"\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e1\u003c\/i\u003ePackaging \u0026amp; sealing machinery\u003c\/h4\u003e\n\u003cp\u003eSealing-jaw and shrink-tunnel temperature on form\/fill\/seal, band sealers and L-bar sealers. Relay output drives the contactor directly; AL2 trips the stack light on deviation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e2\u003c\/i\u003ePlastics extrusion \u0026amp; injection\u003c\/h4\u003e\n\u003cp\u003eBarrel and die-zone control where SSR drive (AK1620 \/ AK220T) fires a 40 A SSR, and RS-485 feeds setpoints down from the machine PLC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e3\u003c\/i\u003eIndustrial ovens \u0026amp; heat treat\u003c\/h4\u003e\n\u003cp\u003eBatch ovens, cure ovens and small electric furnaces. Soft start and auto-tune hold ±1 °F on a 300 lb load; CYPT timer ends the soak and asserts alarm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e4\u003c\/i\u003eHot-runner \u0026amp; heating bands\u003c\/h4\u003e\n\u003cp\u003eMulti-zone hot-runner manifolds and band-heater barrels, one 48×48 controller per zone, 0-10 V output driving an SCR firing board on larger zones.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e5\u003c\/i\u003eFood \u0026amp; beverage process\u003c\/h4\u003e\n\u003cp\u003eKettle, jacketed tank and proofing-room control with 100 Ω Pt RTD and 4-20 mA retransmission to the plant recorder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e6\u003c\/i\u003eIncubators \u0026amp; agricultural\u003c\/h4\u003e\n\u003cp\u003eHatchery and grow-room control, °F-native display, two-stage heat\/cool from the AK1224 dual-relay version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003e7\u003c\/i\u003eOEM \/ machine-builder panels\u003c\/h4\u003e\n\u003cp\u003eDrop-in 45×45 mm cutout, 24 VAC\/DC supply option and a published Modbus map make the TX6A a one-line BOM item for UL 508A control panels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e9 \/ 18\u003c\/div\u003e\n\"\u0026gt;\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eApplications\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e7\u003c\/span\u003e Sizing the Output to the Load\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eMatch the output stage to the heater, not the other way round\u003c\/div\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 24%;\"\u003e \u003ccol style=\"width: 26%;\"\u003e \u003ccol style=\"width: 50%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput type\u003c\/th\u003e\n\u003cth\u003ePractical load range\u003c\/th\u003e\n\u003cth\u003eTypical application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral relay (3 A)\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5 kW @ 240 VAC resistive\u003c\/td\u003e\n\u003ctd\u003eSmall ovens, sealer jaws, solenoid and contactor pilot duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSR drive + external SSR\u003c\/td\u003e\n\u003ctd\u003e1.5 - 15 kW single phase\u003c\/td\u003e\n\u003ctd\u003eExtrusion barrels, platen heaters, mid-size batch ovens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSR drive + SCR firing board\u003c\/td\u003e\n\u003ctd\u003e15 kW+ or 3-phase\u003c\/td\u003e\n\u003ctd\u003eLarge ovens, heat-treat furnaces, multi-zone process skids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-10 V \/ 4-20 mA analog\u003c\/td\u003e\n\u003ctd\u003eAny, via external power controller\u003c\/td\u003e\n\u003ctd\u003eExisting analog plant, SCR\/thyristor packs, PLC setpoint cascading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"note\"\u003e\n\u003cb\u003eAlarm modes (17):\u003c\/b\u003e deviation \/ absolute \/ band, high \u0026amp; low, heater-current LBAT, sensor break and timer-end, with latching variants. \u003ccode\u003eAH1\u003c\/code\u003e\/\u003ccode\u003eAH2\u003c\/code\u003e set hysteresis; the alarm contact is rated 3 A @ 250 VAC resistive — pilot-duty a contactor or stack light, never switch a heater directly.\u003c\/div\u003e\n\u003cdiv class=\"callout\"\u003e\n\u003cb\u003eRule of thumb for North American 240 VAC single-phase loads:\u003c\/b\u003e ≤1.5 kW @240 VAC → relay; 1.5-15 kW → SSR-drive + heatsinked SSR (1.5× current); 15 kW+ \/ 3-phase → SCR firing board. Inductive loads derate the relay to ~50%.\u003c\/div\u003e\n\u003cdiv class=\"pf\"\u003eYHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e10 \/ 18\u003c\/div\u003e\n\u003c!-- ============ P8 REPLACEMENT ============ --\u003e \"\u0026gt;\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eReplacement Guide\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e8\u003c\/span\u003e Drop-In Replacement Guide\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eSame 45×45 mm cutout — swap the instrument, not the panel\u003c\/div\u003e\n\u003cp class=\"lead\"\u003eMost TX6A orders are replacements. Every controller below shares the 45 × 45 mm panel cutout, so the mechanical changeover is a screwdriver job. The electrical check is three items: supply voltage, sensor type, and output device.\u003c\/p\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 24%;\"\u003e \u003ccol style=\"width: 14%;\"\u003e \u003ccol style=\"width: 62%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eReplacing\u003c\/th\u003e\n\u003cth\u003eCutout\u003c\/th\u003e\n\u003cth\u003eWhat to check on changeover\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutonics TC4S \/ TCN4S\u003c\/td\u003e\n\u003ctd\u003e45×45 mm\u003c\/td\u003e\n\u003ctd\u003eSame cutout, same terminal order (power 1-2, input 3-4, OUT1 5-6, OUT2 7-8). Swap the bezel, re-enter the sensor type, run auto-tune.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmron E5CC \/ E5CN\u003c\/td\u003e\n\u003ctd\u003e45×45 mm\u003c\/td\u003e\n\u003ctd\u003eMatch supply voltage on the ordering code — 100-240 VAC standard, or -LV for the 24 VAC\/DC cabinet. Reuse the existing SSR; the 12 V DC drive is compatible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelta DTB4848\u003c\/td\u003e\n\u003ctd\u003e45×45 mm\u003c\/td\u003e\n\u003ctd\u003eTX6-AK1220 \/ AK1224 cover the RR dual-relay variants; AK1620 covers the SR relay-plus-SSR build.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShimaden SR1 \/ SR3\u003c\/td\u003e\n\u003ctd\u003e45×45 mm\u003c\/td\u003e\n\u003ctd\u003eSensor type and alarm mode are re-selected in one menu pass; CYPT replaces the built-in timer function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWest 6100 \/ Cal 9400\u003c\/td\u003e\n\u003ctd\u003e45×45 mm\u003c\/td\u003e\n\u003ctd\u003eNote the West 6100 uses a deeper case — check 75 mm behind-panel clearance before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREX-C100 \/ generic 48×48\u003c\/td\u003e\n\u003ctd\u003e45×45 mm\u003c\/td\u003e\n\u003ctd\u003eUpgrade path for low-cost controllers: adds universal input, dual alarm, timer and Modbus in the same hole.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin-top: 4mm;\"\u003eChangeover procedure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDe-energise and lock out.\u003c\/b\u003e Photograph the rear terminal strip before removing a single wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRecord the old setup.\u003c\/b\u003e Sensor type, SV, alarm setpoints, output action (heat\/cool), and any tuned P\/I\/D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTransfer the wiring\u003c\/b\u003e in terminal order: 1-2 supply · 3-4 sensor input · 5-6 OUT1 · 7-8 OUT2 · A-B RS-485.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSet the input type and the °F\/°C scale\u003c\/b\u003e before applying power — a wrong sensor type reads as a wild PV, not as an error.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRun auto-tune once\u003c\/b\u003e with the real load installed and the door closed. Expect one overshoot cycle; the controller then writes P, I and D itself.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVerify the alarm path\u003c\/b\u003e by forcing a deviation, then set \u003ccode\u003eLOCK\u003c\/code\u003e and file the parameter printout with the machine records.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"pf\"\u003eYHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e11 \/ 18\u003c\/div\u003e\n\"\u0026gt;\n\u003cdiv class=\"rh\"\u003e\n\u003cb\u003eYHKJ · TX6A 1\/16 DIN PID Controller\u003c\/b\u003e\u003cspan\u003eFAQ\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan class=\"no\"\u003e11\u003c\/span\u003e Frequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eThe questions our application engineers answer every week\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eWill the TX6A fit the hole left by my Autonics TC4S?\u003c\/h4\u003e\n\u003cp\u003eYes. Both use a 45 × 45 mm (1.77 × 1.77 in) panel cutout and a 48 × 48 mm bezel. Reuse the existing bracket and gasket; the rear terminals follow the same power \/ input \/ output order, so rewiring is a like-for-like transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eIs the display in Fahrenheit?\u003c\/h4\u003e\n\u003cp\u003e°F is the default on North American shipments; switch to °C in the user menu at any time. The °F\/°C LED on the faceplate shows which scale is active.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eWhich output do I order for a solid-state relay?\u003c\/h4\u003e\n\u003cp\u003eOrder any code-2 or code-5 model — TX6-AK1620 (no comms) or TX6-AK220T (RS-485). Both deliver a 12 V DC pulse at ≈ 20 mA, which drives any standard panel-mount SSR with a DC input. Do not use the relay-output models to fire an SSR input directly without confirming the input current.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eMy heater is 10 kW — relay or SSR?\u003c\/h4\u003e\n\u003cp\u003eAbove roughly 1.5 kW resistive at 240 VAC, use the SSR-drive version with a properly heatsinked SSR (or an SCR firing board for 3-phase). The integral 3 A relay is rated for pilot duty and small resistive loads only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eDoes it carry UL listing?\u003c\/h4\u003e\n\u003cp\u003eThe controller is built to UL 60730-1 \/ UL 60730-2-9 requirements. The standard North American offering is supplied as a UL Recognized Component (UR) for integration into UL 508A panels, with a panel-build support pack on request. Where a stand-alone UL Listed unit or cUL is contractually required, confirm the certificate status with your YHKJ sales contact before releasing the BOM — approval scope and SCCR data must be verified against the current UL Product iQ file, never assumed from the CE mark.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eCan I log data to my SCADA?\u003c\/h4\u003e\n\u003cp\u003eYes, on any model with the T suffix. RS-485 Modbus RTU, address 1-100, 2400-38.4 kbaud. Register map ships as a PDF and as a CSV for direct import.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eWhat is the heater-break alarm, and do I need it?\u003c\/h4\u003e\n\u003cp\u003eThe LBAT function watches for a heater that has gone open-circuit or an SSR that has failed short. For unattended ovens and any process where a cold part is scrap, specify the AK1224 dual-relay version and wire AL2 as the heater-fail output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eHow do I stop the temperature overshooting on a small oven?\u003c\/h4\u003e\n\u003cp\u003eRun auto-tune (AT) once with the door closed and the real load in place, then raise FIL if the PV is noisy and add soft start if the elements are large. On very low thermal-mass loads, reduce the integral time rather than the proportional band.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eWhat is the lead time in North America?\u003c\/h4\u003e\n\u003cp\u003eRelay and SSR versions are the fastest-moving SKUs and are typically stocked state-side; analog and dual-alarm builds ship factory-direct. Confirm current stock and the incoterm applicable to your order (FOB \/ DDP) with your sales contact.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003ch4\u003e\n\u003ci\u003eQ\u003c\/i\u003eWhat warranty and support do I get?\u003c\/h4\u003e\n\u003cp\u003e24 months from shipment against defects in materials and workmanship. Every order includes the full parameter list, wiring diagram and Modbus map; remote commissioning support is available during business hours ET.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pf\"\u003eYHKJ Automation · TX6A-NA-DS-001 Rev D · Subject to change without notice\u003c\/div\u003e\n\u003cdiv class=\"pn\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"electrical center b2c","offers":[{"title":"TX6-AK1220\/ Relay","offer_id":50985033138369,"sku":"TX6-AK1220\/ Relay autonics tc4s alternative","price":47.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK1224\/ Relay Dual-alarm","offer_id":50985033171137,"sku":"TX6-AK1224\/ Relay Dual-alarm autonics tcn4s replacement","price":50.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK320\/ SSR-PID 4-20mA","offer_id":50985033203905,"sku":"TX6-AK320\/ SSR-PID 4-20mA omron e5cc replacement","price":51.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK1620\/ Relay 4-20mA","offer_id":50985033236673,"sku":"TX6-AK1620\/ Relay 4-20mA omron e5cn replacement","price":57.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK120T\/ Relay with RS485","offer_id":50985033269441,"sku":"TX6-AK120T\/ Relay with RS485 shimaden sr1-8p replacement","price":82.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK220T\/ SSR with RS485","offer_id":50985033302209,"sku":"TX6-AK220T\/ SSR with RS485 delta dtb4848 alternative","price":82.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK320T\/ PID 4-20mA with RS485","offer_id":50985033334977,"sku":"TX6-AK320T\/ PID 4-20mA with RS485 west 6100+ replacement","price":87.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK420\/ SSR PID 0-10V","offer_id":50985033367745,"sku":"TX6-AK420\/ SSR PID 0-10V inoxtronic tr1 alternative","price":51.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK2520\/ Relay 0-10V","offer_id":50985033400513,"sku":"TX6-AK1520\/ Relay 0-10V INKBIRD ITC-100RH alternative","price":57.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AA320\/ PID 4-20mA(IN \u0026 OUT)","offer_id":50985033433281,"sku":"TX6-AA320\/ PID 4-20mA(IN \u0026 OUT) replacement for discontinued 48x48 pid controller","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/imgi_111_Sbd89a0afa67b4239bcf8e73b5934e645d.jpg?v=1795069077","url":"https:\/\/www.electric-b2c.com\/products\/tx6a-series-1-16-din-pid-temperature-controller-replacement-for-discontinued-48x48-pid-controller","provider":"electrical center b2c","version":"1.0","type":"link"}