{"product_id":"tx6-e-1-4-din-pid-temperature-controller","title":"YHKJ TX6-E 1\/4 DIN PID Temperature Controller | 92×92 Cutout, 75mm Universal Thermocouple \u0026 RTD input · relay \/ SSR \/ 0-10 V \/ 4-20 mA output · RS-485 Modbus","description":"\u003ch1\u003e1\/4 din temperature controller ,92x92 cutout temperature controller  ,quarter din temperature controller ,low depth panel temperature controller 96x96, large oven pid controller 1\/4 din ,extruder barrel zone controller 96x96 \u003c\/h1\u003e\n\u003ch2\u003eshimaden sr93 replacement, sr93 alternative shallower depth 1\/4 din, rkc ch902 replacement, pid temperature controller rkc cd901 alternative, 96x96 omron e5ac replacement, 1\/4 din temperature controller autonics tk4l alternative, 96x96 pid delta dta9696r replacement, temperature controller fotek mt96 replacement, 1\/4 din 1\/4 din dial thermostat upgrade to pid analog, 96x96 controller replace with digital pid\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe TX6-E is a panel-mounted PID temperature controller in a 96 × 96 mm case with a 92 × 92 mm cutout. It is the largest and most common panel format in the family, and unlike its TX6-D stablemate it \u003c\/span\u003e\u003cb\u003eis\u003c\/b\u003e\u003cspan\u003e a genuine DIN 43700 size: 96 × 96 mm face, 92 × 92 mm cutout, one loop given the whole door. You choose it when one loop is worth a cabinet door of its own — a batch oven, a heat-treat furnace, an environmental chamber, a large extruder zone. The 1\/4 DIN face carries the biggest characters in the TX6 range, readable from across a furnace floor, with PV \/ SV \/ MV on three separate lines so the operator sees not just the setpoint but whether the controller is actually firing. It is also where the depth fight matters most: the Japanese and Korean 1\/4 DIN instruments this replaces sit 100 mm behind the panel, and the TX6-E sits 75 mm, so a shallow cabinet that would not close now closes. Same electronics as the TX6A \/ TX6B \/ TX6-E, one part-number logic, one parameter list, one Modbus map.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/YHKJ_TX6E_Temperature_Controller_NA_DetailPage_EN_RevA.pdf?v=1795419549\" target=\"_blank\" title=\"heat treat furnace temperature controller, 96x96 environmental chamber controller, 1\/4 din walk in oven temperature controller pid, extruder barrel zone controller 96x96 \" rel=\"noopener\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eTX6E Product DATA SHEET Download\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e\n\u003ch2\u003eAvailable Configurations\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003eTen factory builds — pick the output, then the options\u003c\/div\u003e\n\u003cp\u003eAll ten share the same 96 × 96 mm case, the same 92 × 92 mm cutout, the same universal input and the same 75 mm depth. They differ only in what they drive and whether they can talk.\u003c\/p\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eOutput 1\u003c\/th\u003e\n\u003cth\u003eOutput 2\u003c\/th\u003e\n\u003cth\u003eComms\u003c\/th\u003e\n\u003cth\u003eAlarm\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK1220\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay 3 A\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose 1\/4 DIN drop-in; direct contactor or pilot-duty switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK1224\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay 3 A\u003c\/td\u003e\n\u003ctd\u003eRelay 3 A\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1 + AL2\u003c\/td\u003e\n\u003ctd\u003eTwo-stage heat\/cool, or one control stage plus a fully independent high-limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK120T\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay 3 A\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eStand-alone machine reporting SV, PV and alarm state to the plant PLC or HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK1620\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eSSR drive 12 V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eSSR + heatsink firing, zero-cross switching, silent and long-life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK220T\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eSSR drive 12 V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eMulti-zone networked ovens and extrusion barrels under PLC supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK420\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e0-10 V DC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eAnalog setpoint input or SCR firing-board drive on an existing 0-10 V plant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK1520\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003eRelay 3 A\u003c\/td\u003e\n\u003ctd\u003e0-10 V DC\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eRelay for the contactor stage with analog retransmission to a recorder or second controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK320\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eLong-run analog retransmission to a PLC analog input or chart recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EK320T\u003c\/td\u003e\n\u003ctd\u003eTC \/ RTD universal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003eFull traceability — analog loop plus Modbus supervisory on one part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX6-EA320\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (process)\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAL1\u003c\/td\u003e\n\u003ctd\u003ePressure, flow or level loop indicated and controlled in engineering units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"callout\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"callout\"\u003e\n\u003cb\u003eOutput 2 is free only on two codes.\u003c\/b\u003e \u003ccode\u003eTX6-EK1224\u003c\/code\u003e (relay + relay) gives you a real second stage or a fully independent high-limit alarm. \u003ccode\u003eTX6-EK1520\u003c\/code\u003e (relay + 0-10 V) gives you a contactor stage with analog retransmission. Every other code is single-output — if your circuit needs two, do not try to parallel the terminals.\u003c\/div\u003e\n\u003cdiv class=\"note\"\u003e\n\u003cb\u003eSupply voltage:\u003c\/b\u003e 100-240 VAC 50\/60 Hz is standard. For a 24 VAC or 24 VDC control cabinet, append \u003ccode\u003e-LV\u003c\/code\u003e to the part code and state it explicitly on the PO — a 24 V unit ordered without the suffix arrives as 120\/240 V.\u003c\/div\u003e\n\u003cdiv class=\"note\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"note\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"note\"\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cdiv class=\"kick\"\u003e96 × 96 × 75 mm housing · 100-240 VAC · 0-50 °C\u003c\/div\u003e\n\u003cdiv class=\"tw\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel format\u003c\/td\u003e\n\u003ctd\u003e96 × 96 mm (3.78 × 3.78 in) — 1\/4 DIN, IEC \/ DIN 43700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel cutout\u003c\/td\u003e\n\u003ctd\u003e92 × 92 mm (3.622 × 3.622 in), + tolerance TBC — verify against the factory dimensional drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase depth\u003c\/td\u003e\n\u003ctd\u003e75 mm (2.95 in) behind panel; overall 96 × 96 × 75 mm; overall with terminal cover TBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mount with two supplied clamping brackets; panel thickness TBC (typical 1.0-6.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3-line LED: PV (white, upper), SV (green, middle), MV output % (orange, lower); 8-segment output bar; OC \/ AL1 \/ AL2 lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay characters\u003c\/td\u003e\n\u003ctd\u003ePV \/ SV 4 digits, 12 mm (0.47 in) red\/white-green LED — TBC against factory drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eMODE, shift, ▲, ▼ — sealed membrane front, IP rating TBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003ePID (with auto-tune) or ON\/OFF; heat (reverse) or cool (direct); soft-start ramp; timer program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling period\u003c\/td\u003e\n\u003ctd\u003eTBC — confirm before specifying for fast loops (reference: Autonics TK4L 50 ms, Delta DTA9696 0.5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC, 50\/60 Hz (standard) · 24 VAC\/VDC optional (-LV); consumption TBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation \/ dielectric\u003c\/td\u003e\n\u003ctd\u003eTBC per factory test spec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 35-85 % RH non-condensing — TBC per factory spec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum mounting pitch\u003c\/td\u003e\n\u003ctd\u003eTBC — side-by-side and vertical spacing on multi-zone panels; confirm against heat-rise data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e130G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e24 months from shipment against defects in materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"callout\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"callout\"\u003e\n\u003cb\u003eEvery value marked TBC is unverified on this family.\u003c\/b\u003e This is first issue for the 1\/4 DIN format, and we would rather leave a hole in the table than fill it with a number we cannot stand behind. Samples, accuracy class, sampling period, the front-panel IP\/NEMA rating and heater-break capability are the five that change buying decisions — get them in writing from your sales contact before releasing a BOM or quoting guaranteed performance.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"electrical center b2c","offers":[{"title":"TX6-EK1220\/ Relay","offer_id":51005903929537,"sku":null,"price":49.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK1224\/ Relay Dual-alarm","offer_id":51005903962305,"sku":null,"price":52.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK320\/ SSR-PID 4-20mA","offer_id":51005903995073,"sku":null,"price":53.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK1620\/ Relay 4-20mA","offer_id":51005904027841,"sku":null,"price":59.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK120T\/ Relay with RS485","offer_id":51005904060609,"sku":null,"price":84.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK220T\/ SSR with RS485","offer_id":51005904093377,"sku":null,"price":84.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK320T\/ PID 4-20mA with RS485","offer_id":51005904126145,"sku":null,"price":89.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK420\/ SSR PID 0-10V","offer_id":51005904158913,"sku":null,"price":53.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EK1520\/ Relay 0-10V","offer_id":51005904191681,"sku":null,"price":59.0,"currency_code":"USD","in_stock":true},{"title":"TX6-EA320\/ PID 4-20mA(IN \u0026 OUT)","offer_id":51005904224449,"sku":null,"price":84.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/TX6-EK1220.webp?v=1795418354","url":"https:\/\/www.electric-b2c.com\/products\/tx6-e-1-4-din-pid-temperature-controller","provider":"electrical center b2c","version":"1.0","type":"link"}