{"product_id":"tc4s-alternative","title":"TC4S Alternative | TX6A 1\/16 DIN PID, 45x45 Cutout PID Controller","description":"\u003ch1\u003e\u003cspan\u003eTC4S, TCN4S \u0026amp; TK4S Alternative — Same 45×45 mm Cutout, Lower Landed Cost\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe Autonics TC4S, TCN4S and TK4S are three of the most widely specified 1\/16 DIN PID controllers in North America — and through distribution they typically land between \u003cstrong\u003eUS$95 and US$130\u003c\/strong\u003e per unit, with lead times that stretch on the SSR and RS-485 variants. If you are fitting out a panel, retrofitting a machine, or simply replacing a failed unit on a Saturday, the TX6A gives you the same 45×45 mm cutout, the same universal thermocouple\/RTD input list, and the same choice of relay, SSR-drive, 0–10 V and 4–20 mA outputs — at a fraction of the landed cost, with sample quantities available from one piece.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eWhy buyers switch\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame cutout, no panel rework.\u003c\/strong\u003e 45.0×45.0 mm (+0.6 mm) is the 1\/16 DIN standard. The TX6A drops into an existing TC4S\/TCN4S\/TK4S aperture with no machining.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame sensor list.\u003c\/strong\u003e J, K, T, R, S, B, E, N thermocouples plus Pt100\/Cu50 RTD, and a dedicated 4–20 mA process-input variant (TX6-AA320) for pressure, flow and level loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour output families in ten part numbers.\u003c\/strong\u003e Relay, SSR drive (12 VDC), 0–10 V and 4–20 mA, with single or dual alarm, and RS-485 Modbus RTU on the “T” suffixes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-tuning and digital filtering.\u003c\/strong\u003e AT identifies P\/I\/D on the real load; the FIL parameter damps noisy PV signals so the output does not chatter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample-then-scale.\u003c\/strong\u003e One unit for evaluation, volume pricing from 10 pcs, shipped from the Yiwu, Zhejiang warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecification cross-reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eAutonics TC4S \/ TCN4S \/ TK4S\u003c\/th\u003e\n\u003cth\u003eYHKJ TX6A\u003c\/th\u003e\n\u003cth\u003eSwap impact\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003e48 × 48 mm\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003e48 × 48 mm\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel cutout\u003c\/td\u003e\n\u003ctd\u003e45 × 45 mm\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003e45 × 45 mm (+0.6)\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eNo panel rework\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel depth\u003c\/td\u003e\n\u003ctd\u003e64.5 mm\u003c\/td\u003e\n\u003ctd class=\"mut\"\u003eTBC — confirm against drawing\u003c\/td\u003e\n\u003ctd\u003ePublish the measured figure before launch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eTCN4S: dual 4-digit PV\/SV\u003cbr\u003eTC4S\/TK4S: single\/dual by suffix\u003c\/td\u003e\n\u003ctd\u003eDual 4-digit, PV red \/ SV green, MV bar\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eSuperset — no loss of readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple input\u003c\/td\u003e\n\u003ctd\u003eK, J, T, R, S, B, E, N, C, L, U, PLII\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, R, S, B, E, N\u003c\/td\u003e\n\u003ctd\u003eCheck C \/ L \/ U \/ PLII on the old spec before swapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD input\u003c\/td\u003e\n\u003ctd\u003ePt100 Ω, Cu50Ω (DPt100 on -12 suffix)\u003c\/td\u003e\n\u003ctd\u003ePt100, Cu50\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eCompatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003ctd\u003e4–20 mA \/ 0–10 V by suffix\u003c\/td\u003e\n\u003ctd\u003e4–20 mA on TX6-AA320\u003c\/td\u003e\n\u003ctd\u003eConfirm loop power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl output\u003c\/td\u003e\n\u003ctd\u003eRelay 250 VAC 3 A \/ SSR drive 12 VDC \/ 4–20 mA \/ 0–10 V \/ SCR trigger\u003c\/td\u003e\n\u003ctd\u003eRelay \/ SSR 12 V \/ 0–10 V \/ 4–20 mA\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eAll four families covered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl mode\u003c\/td\u003e\n\u003ctd\u003ePID \/ ON-OFF, auto-tune\u003c\/td\u003e\n\u003ctd\u003ePID \/ ON-OFF, AT, digital filter FIL\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eRe-tune on install\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms\u003c\/td\u003e\n\u003ctd\u003eUp to 3 (TC4S), 17 modes\u003c\/td\u003e\n\u003ctd\u003eAL1 single, or AL1+AL2 dual (suffix 4)\u003c\/td\u003e\n\u003ctd\u003eMap AL1\/AL2 to the original functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus RTU\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus RTU, addr 1–247, 1.2–115.2 kbps (“T” suffix)\u003c\/td\u003e\n\u003ctd class=\"no\"\u003eRe-point the SCADA register map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC 50\/60 Hz, optionally 12–24 VDC\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC standard; 24 VAC\/VDC as \u003ccode class=\"inline\"\u003e-LV\u003c\/code\u003e\n\u003c\/td\u003e\n\u003ctd\u003eMeasure at the terminals before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, RoHS; UL on request\u003c\/td\u003e\n\u003ctd\u003eDesigned to UL 60730-1 \/ 60730-2-9, supplied as UL Recognized Component for UL 508A panels; UL Listed TBC\u003c\/td\u003e\n\u003ctd class=\"no\"\u003eDo not claim UL Listed until the file number is issued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"tbl-note\"\u003eAutonics data from published TC4S \/ TCN4S \/ TK4S datasheets and North American distributor listings; TX6A data from the YHKJ TX6 series documentation. Suffix lettering and terminal positions must be re-checked against the nameplate of the unit being replaced.\u003c\/p\u003e\n\u003ch2\u003eOrder the equivalent part number\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIf you are replacing…\u003c\/th\u003e\n\u003cth\u003eOrder this TX6A\u003c\/th\u003e\n\u003cth\u003eOutput \/ alarms\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC4S-14R \/ TC4S-24R (relay)\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK1220\u003c\/td\u003e\n\u003ctd\u003eRelay, single alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC4S with dual alarm\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK1224\u003c\/td\u003e\n\u003ctd\u003eRelay, AL1 + AL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTCN4S-14R with comms\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK120T\u003c\/td\u003e\n\u003ctd\u003eRelay + RS-485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC4S-14S \/ SSR-drive variant\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK1620\u003c\/td\u003e\n\u003ctd\u003eSSR drive 12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTCN4S-24S with comms\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK220T\u003c\/td\u003e\n\u003ctd\u003eSSR drive + RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC4S 0–10 V analogue output\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK2520\u003c\/td\u003e\n\u003ctd\u003e0–10 V + relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC4S 4–20 mA output\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AK320 \/ TX6-AK320T\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, “T” adds RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC4S process-input (4–20 mA in)\u003c\/td\u003e\n\u003ctd class=\"hi\"\u003eTX6-AA320\u003c\/td\u003e\n\u003ctd\u003e4–20 mA in \/ 4–20 mA out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSix steps to a clean swap\u003c\/h2\u003e\n\u003cdiv class=\"steps\"\u003e\n\u003cdiv class=\"step\"\u003e\u003cb\u003ePhotograph the nameplate\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cspan\u003eRecord the full ordering code including every suffix letter — the same base model with a different suffix is a different output board.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cb\u003eMeasure supply at the terminals\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cspan\u003e120 \/ 240 VAC on the North American site, or 24 VDC from the panel PSU. Order \u003ccode class=\"inline\"\u003e-LV\u003c\/code\u003e if it is 24 V.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cb\u003eConfirm the sensor and its range\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cspan\u003eThermocouple type, 2- vs 3-wire RTD, and whether the scale is °C or °F. TX6 is selectable °C\/°F.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cb\u003eMeasure free panel depth\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cspan\u003eFrom the inside of the cutout to the deepest obstruction. Compare with the TX6A drawing before ordering, not after.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cb\u003eCheck whether the analogue output is actually used\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cspan\u003eMany legacy panels specify a 4–20 mA output that was never wired. If it is wired, match the output family exactly.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cb\u003eDe-energise, rewire, re-tune\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"step\"\u003e\u003cspan\u003eTerminal order is 1\u0026amp;2 supply \/ 3\u0026amp;4 input \/ 5\u0026amp;6 OUT1 \/ 7\u0026amp;8 OUT2 \/ A\u0026amp;B RS-485. Set SnPb, dP and Ar to match the old unit, then run auto-tune on the real load.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"box warn\"\u003e\u003cspan class=\"bt\"\u003eRewiring is always required\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"box warn\"\u003e\n\u003cb\u003eNo two brands share a terminal map.\u003c\/b\u003e Even when the cutout is identical, the TX6A terminal order differs from the Autonics layout. Treat this as a re-termination job, not a pull-and-push swap, and re-run auto-tuning before returning the machine to production.\u003c\/div\u003e\n\u003cdiv class=\"box warn\"\u003e\u003c\/div\u003e\n\u003ch2 class=\"box warn\"\u003eFrequently asked questions\u003c\/h2\u003e\n\u003csection class=\"page\" id=\"p1\"\u003e\n\u003cdiv class=\"wrap\"\u003e\n\u003cdiv class=\"faq\"\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWill the TX6A fit the hole left by a TC4S?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. Both use the 1\/16 DIN standard 45.0×45.0 mm cutout with +0.6 mm tolerance. No panel machining is needed. Confirm the free depth behind the panel against the TX6A outline drawing before ordering.\u003c\/p\u003e\n\u003cslot id=\"details-content\"\u003e\u003c\/slot\u003e\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eDo I need a different part number for a TCN4S vs a TC4S?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo — the cutout and depth are the same across TC4S, TCN4S and TK4S. Choose the TX6A part number by \u003cem\u003efunction\u003c\/em\u003e instead: output type, number of alarms, and whether RS-485 is required.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eCan I connect my existing K-type thermocouple directly?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. Terminals 3 and 4 accept J, K, T, R, S, B, E and N thermocouples as well as Pt100\/Cu50 RTDs. Set the input type parameter to match the sensor, and use the correct compensation if you are extending the thermocouple with non-TC cable.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWill my Modbus network still work?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe TX6A speaks Modbus RTU over RS-485 on the “T” suffixed models, address 1–247, 1.2–115.2 kbps. The protocol is standard, but the register map is not shared with Autonics — you will need to re-point the HMI or SCADA tags. Allow for that in the changeover window.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat about the 4–20 mA output my PLC reads?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eOrder the TX6-AK320 (or TX6-AK320T if you also need RS-485). If the loop is sourced by the controller, confirm the loop load budget against the PLC analogue input impedance before commissioning.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eIs this a genuine Autonics part?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo. The TX6A is an independent product of YHKJ, sold by Electrical Center B2C. Autonics® is a trademark of its respective owner. The model names appear here only to identify equipment the TX6A is mechanically and functionally compatible with.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"back\"\u003e\n\u003cdiv class=\"wrap\"\u003e\n\u003cp class=\"copy\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"electrical center b2c","offers":[{"title":"TX6-AK1220\/ Relay","offer_id":50998047310017,"sku":"TC4S-14R \/ TC4S-24R (relay)","price":47.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK1224\/ Relay Dual-alarm","offer_id":50998047342785,"sku":"TC4S with dual alarm","price":50.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK320\/ SSR-PID 4-20mA","offer_id":50998047375553,"sku":"TC4S 4–20 mA output","price":51.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK1620\/ Relay 4-20mA","offer_id":50998047408321,"sku":"TC4S-14S \/ SSR-drive variant","price":57.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK120T\/ Relay with RS485","offer_id":50998047441089,"sku":"TCN4S-14R with comms","price":82.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK220T\/ SSR with RS485","offer_id":50998047473857,"sku":"TCN4S-24S with comms","price":82.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK320T\/ PID 4-20mA with RS485","offer_id":50998047506625,"sku":"TC4S 4–20 mA output with rs485","price":87.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK420\/ SSR PID 0-10V","offer_id":50998047539393,"sku":"TX6-AK420\/ SSR PID 0-10V","price":51.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AK2520\/ Relay 0-10V","offer_id":50998047572161,"sku":"TC4S 0–10 V analogue output","price":57.0,"currency_code":"USD","in_stock":true},{"title":"TX6-AA320\/ PID 4-20mA(IN \u0026 OUT)","offer_id":50998047604929,"sku":"TC4S process-input (4–20 mA in)","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/imgi_111_Sbd89a0afa67b4239bcf8e73b5934e645d.jpg?v=1795069077","url":"https:\/\/www.electric-b2c.com\/products\/tc4s-alternative","provider":"electrical center b2c","version":"1.0","type":"link"}