{"product_id":"schneider-acti9-a9-series-icnv-self-recovery-over-under-voltage-protector-household-2p-4p","title":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector, Household 2P \/ 4P","description":"\u003cp\u003eSchneider Acti9 iCNV self-recovery overvoltage \u0026amp; undervoltage protector matches IC65N MCB perfectly. It automatically cuts off power when grid voltage exceeds 275V or drops below 160V to protect home appliances, air conditioners, refrigerators and sensitive electronics. After voltage returns to safe range, the unit auto-recloses within 25-35s without manual operation. DIN rail modular design, IP20 safe housing, 2P single phase \u0026amp; 4P three phase optional, widely used in household and commercial distribution boxes.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eItem NO (Order Code A9C69xxxx)\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4\u003e2P (1P+N, Single Phase 230V Home Use)\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eFull Model\u003c\/th\u003e\n\u003cth\u003eItem NO\u003c\/th\u003e\n\u003cth\u003eModular Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eiCNV 2P 25A\u003c\/td\u003e\n\u003ctd\u003eA9C69225\u003c\/td\u003e\n\u003ctd\u003e36mm (4 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eiCNV 2P 32A\u003c\/td\u003e\n\u003ctd\u003eA9C69232\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eiCNV 2P 40A\u003c\/td\u003e\n\u003ctd\u003eA9C69240\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eiCNV 2P 50A\u003c\/td\u003e\n\u003ctd\u003eA9C69250\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eiCNV 2P 63A\u003c\/td\u003e\n\u003ctd\u003eA9C69263\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003ctd\u003eiCNV 2P 80A\u003c\/td\u003e\n\u003ctd\u003eA9C69280\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e4P (3P+N, Three Phase 400V)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eFull Model\u003c\/th\u003e\n\u003cth\u003eItem NO\u003c\/th\u003e\n\u003cth\u003eModular Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003eiCNV 4P 25A\u003c\/td\u003e\n\u003ctd\u003eA9C69425\u003c\/td\u003e\n\u003ctd\u003e72mm (8 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eiCNV 4P 32A\u003c\/td\u003e\n\u003ctd\u003eA9C69432\u003c\/td\u003e\n\u003ctd\u003e72mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eiCNV 4P 40A\u003c\/td\u003e\n\u003ctd\u003eA9C69440\u003c\/td\u003e\n\u003ctd\u003e72mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003eiCNV 4P 50A\u003c\/td\u003e\n\u003ctd\u003eA9C69450\u003c\/td\u003e\n\u003ctd\u003e72mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eiCNV 4P 63A\u003c\/td\u003e\n\u003ctd\u003eA9C69463\u003c\/td\u003e\n\u003ctd\u003e72mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003ctd\u003eiCNV 4P 80A\u003c\/td\u003e\n\u003ctd\u003eA9C69480\u003c\/td\u003e\n\u003ctd\u003e72mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Attribute Sheet \u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute Category\u003c\/th\u003e\n\u003cth\u003eAttribute Name\u003c\/th\u003e\n\u003cth\u003eAttribute Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eBasic Product Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eActi9 (A9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eiCNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003eProduct Full Name\u003c\/td\u003e\n\u003ctd\u003eSelf-recovery Overvoltage \u0026amp; Undervoltage Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003eItem NO Prefix\u003c\/td\u003e\n\u003ctd\u003eA9C69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003ePole Configuration Options\u003c\/td\u003e\n\u003ctd\u003e2P(1P+N), 4P(3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003eRated Current Options\u003c\/td\u003e\n\u003ctd\u003e25A, 32A, 40A, 50A, 63A, 80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Product Information\u003c\/td\u003e\n\u003ctd\u003eMatching MCB\u003c\/td\u003e\n\u003ctd\u003eActi9 iC65N Series Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCore Electrical Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated Operational Voltage (2P)\u003c\/td\u003e\n\u003ctd\u003e230V AC 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eRated Operational Voltage (4P)\u003c\/td\u003e\n\u003ctd\u003e400V AC 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Trip Threshold\u003c\/td\u003e\n\u003ctd\u003e275V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Recovery Threshold\u003c\/td\u003e\n\u003ctd\u003e253V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eUndervoltage Trip Threshold\u003c\/td\u003e\n\u003ctd\u003e160V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Electrical Parameters\u003c\/td\u003e\n\u003ctd\u003eUndervoltage Recovery Threshold\u003c\/td\u003e\n\u003ctd\u003e195V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eFunction \u0026amp; Performance Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto Reset Delay Time\u003c\/td\u003e\n\u003ctd\u003e25 ~ 35 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Trip Time (≤63A @275V)\u003c\/td\u003e\n\u003ctd\u003e3 ~ 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Trip Time (80A @275V)\u003c\/td\u003e\n\u003ctd\u003e3 ~ 15s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eExtreme Overvoltage Trip Time (@400V)\u003c\/td\u003e\n\u003ctd\u003e0.1 ~ 0.2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eUndervoltage Trip Time (≤63A)\u003c\/td\u003e\n\u003ctd\u003e0.6 ~ 1.5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eUndervoltage Trip Time (80A)\u003c\/td\u003e\n\u003ctd\u003e0.6 ~ 5s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e10000 Operation Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eCore Feature\u003c\/td\u003e\n\u003ctd\u003eAuto self-reclosing without manual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \u0026amp; Performance Indicators\u003c\/td\u003e\n\u003ctd\u003eIndicator Light Status\u003c\/td\u003e\n\u003ctd\u003eGreen=Normal Operation; Red Flash=OV\/UV Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Standard\u003c\/td\u003e\n\u003ctd\u003e35mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eInstallation Width (2P)\u003c\/td\u003e\n\u003ctd\u003e36mm (4×9mm Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eInstallation Width (4P)\u003c\/td\u003e\n\u003ctd\u003e72mm (8×9mm Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eWiring Direction\u003c\/td\u003e\n\u003ctd\u003eBottom In, Top Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e1.0 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eHousing Color\u003c\/td\u003e\n\u003ctd\u003eWhite RAL9003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eIP Protection Grade\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eProduct Weight (2P)\u003c\/td\u003e\n\u003ctd\u003e~130g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Mechanical Specifications\u003c\/td\u003e\n\u003ctd\u003eProduct Weight (4P)\u003c\/td\u003e\n\u003ctd\u003e~240g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eEnvironmental \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-5°C ~ +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Compliance\u003c\/td\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C ~ +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Compliance\u003c\/td\u003e\n\u003ctd\u003eCompliance Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-5-1, IEC 61000 EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Compliance\u003c\/td\u003e\n\u003ctd\u003eApplication Scenarios\u003c\/td\u003e\n\u003ctd\u003eResidential household distribution box, Commercial lighting circuit, Small machinery power supply protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003ePackaging \u0026amp; SEO Tags\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePackaging Specification\u003c\/td\u003e\n\u003ctd\u003e6pcs per inner box, 48pcs per export carton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging \u0026amp; SEO Tags\u003c\/td\u003e\n\u003ctd\u003eCore Search Tags\u003c\/td\u003e\n\u003ctd\u003eSchneider iCNV, Acti9 A9, Over Under Voltage Protector, Auto Reset OV UV Relay, DIN Rail Voltage Protection, IC65N Matching Voltage Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"electrical center b2c","offers":[{"title":"2P (1P+N) \/ 32A","offer_id":50347670700225,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 2P (1P+N) \/ 32A","price":38.75,"currency_code":"USD","in_stock":true},{"title":"2P (1P+N) \/ 40A","offer_id":50347670732993,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 2P (1P+N) \/ 40A","price":39.58,"currency_code":"USD","in_stock":true},{"title":"2P (1P+N) \/ 50A","offer_id":50347670765761,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 2P (1P+N) \/ 50A","price":40.42,"currency_code":"USD","in_stock":true},{"title":"2P (1P+N) \/ 63A","offer_id":50347670798529,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 2P (1P+N) \/ 63A","price":40.42,"currency_code":"USD","in_stock":true},{"title":"4P (3P+N) \/ 32A","offer_id":50347670831297,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 4P (3P+N) \/ 32A","price":66.25,"currency_code":"USD","in_stock":true},{"title":"4P (3P+N) \/ 40A","offer_id":50347670864065,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 4P (3P+N) \/ 40A","price":67.3,"currency_code":"USD","in_stock":true},{"title":"4P (3P+N) \/ 50A","offer_id":50347670896833,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 4P (3P+N) \/ 50A","price":68.35,"currency_code":"USD","in_stock":true},{"title":"4P (3P+N) \/ 63A","offer_id":50347670929601,"sku":"Schneider Acti9 A9 Series iCNV Self-recovery Over \u0026 Under Voltage Protector 4P (3P+N) \/ 63A","price":68.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/4a7a9004c068615d2de5c30d0da635b5_d111287d-8971-4740-aae8-e7d7f74cf73f.jpg?v=1782011461","url":"https:\/\/www.electric-b2c.com\/products\/schneider-acti9-a9-series-icnv-self-recovery-over-under-voltage-protector-household-2p-4p","provider":"electrical center b2c","version":"1.0","type":"link"}