ABB New GSE200L Series Residual Current Circuit Breaker Overload Short Circuit Protection Household Integrated RCBO, 1P+N / 2P / 3P / 4P Optional
ABB new upgraded GSE200L series integrated leakage circuit breaker, combining overload, short circuit and electric shock leakage protection in one unit. Equipped with standard 30mA AC-type residual current trip, C curve suitable for household appliances, lighting and socket circuits. Multiple pole and current specifications optional, standard DIN rail modular design, easy installation in home distribution boxes, reliable safety protection for residential and light commercial power systems.
Available Pole Options
Rated Current Options
Common Item NO & Model Reference
| Pole | Rated Current | Complete Model | Item NO (Order Code) |
|---|---|---|---|
| 1P+N | 10A | GSE201L AC-C10/0.03 | 10236328 |
| 2P | 63A | GSE202L AC-C63/0.03 | 10236434 |
| 3P | 10A | GSE203L AC-C10/0.03 | 10236332 |
| 4P | 50A | GSE204L AC-C50/0.03 | 10236451 |
Product Attribute Sheet
| Attribute Category | Attribute Name | Attribute Value |
|---|---|---|
| Basic Info | Brand | ABB |
| Basic Info | Product Series | GSE200L (New SE200 family) |
| Basic Info | Product Full Name | Residual Current Circuit Breaker (RCBO) / Earth Leakage Circuit Breaker |
| Basic Info | Product Type | Integrated RCBO (Overload + Short Circuit + Earth Leakage 3-in-1 Protection) |
| Basic Info | Available Pole Configurations | 1P+N, 2P, 3P, 4P |
| Basic Info | Rated Current Range | 6A,10A,16A,20A,25A,32A,40A,50A,63A |
| Electrical Parameter | Rated Operational Voltage | 230V AC 50Hz (1P+N/2P); 400V AC 50Hz (3P/4P) |
| Electrical Parameter | Rated Insulation Voltage Ui | 440V |
| Electrical Parameter | Rated Impulse Withstand Voltage Uimp | 4kV |
| Electrical Parameter | Trip Curve Characteristic | C Curve (Standard Household Type) |
| Electrical Parameter | Standard Residual Operating Current IΔn | 30mA |
| Electrical Parameter | Residual Current Type | AC Type |
| Electrical Parameter | Rated Breaking Capacity Icn | 4.5kA / 6kA |
| Electrical Parameter | Residual Trip Time | Instantaneous ≤40ms at 5×IΔn |
| Mechanical & Mounting | Mounting Standard | 35mm Standard DIN Rail |
| Mechanical & Mounting | Wiring Direction | Top In, Bottom Out |
| Mechanical & Mounting | Terminal Type | Screw Clamp Terminal |
| Mechanical & Mounting | Tightening Torque | 1.2 N·m |
| Mechanical & Mounting | Module Width | 1P+N: 18mm (2mod); 2P:36mm(4mod); 3P:54mm(6mod); 4P:72mm(8mod) |
| Environmental & Compliance | IP Rating | IP20 (Indoor Distribution Box Only) |
| Environmental & Compliance | Operating Temperature | -5°C ~ +40°C |
| Environmental & Compliance | Storage Temperature | -40°C ~ +70°C |
| Environmental & Compliance | Compliance Standards | IEC 60898-1, IEC 61009-1, IEC 61000 EMC |
| Function Feature | Core Functions | Overload protection, Short-circuit protection, Earth leakage/electric shock protection |
| Function Feature | Safety Design | Manual test button for regular leakage function inspection |
| Application Scenario | Usage Field | Household power distribution box, residential lighting & socket circuits, small commercial power system |
| Packaging & SEO | Packaging Spec | 1pc per small box, 40pcs per export carton |
| Packaging & SEO | Core English SEO Tags | ABB GSE200L RCBO, ABB earth leakage circuit breaker, integrated residual current breaker, DIN rail household leakage switch, SE200 series MCB with RCD, C curve 30mA RCBO |