{"product_id":"120v-2p-rccb-residual-current-circuit-breaker-6a-80a-30ma-replacement-earth-leakage-breaker-for-us-residential-distribution-panel","title":"120V 2P RCCB Residual Current Circuit Breaker 6A‑80A 30mA, Replacement Earth Leakage Breaker for US Residential Distribution Panel","description":"\u003ch1\u003eReplacement RCCB for 120v residential panel,120V RCCB\u003c\/h1\u003e\n\u003ch3\u003eUS 120V RCCB 2‑Pole 30mA Residual Current Protector 6A 10A 16A 20A 25A 32A 40A 50A 63A 80A Replacement for Home Electrical Panel\u003c\/h3\u003e\n\u003cp\u003eThis 120V 2‑pole RCCB residual current circuit breaker is a direct‑fit replacement device for US residential electrical panels, covering rated current 6A‑80A and fixed 30mA residual operating current. It delivers ground‑fault leakage protection for household circuits, complies with North‑American low‑voltage residential application requirements. It serves as safety upgrade or drop‑in replacement for existing RCCB units for 120V single‑phase living space wiring.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eRated electrical specifications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThis RCCB is designed for 120V US residential single‑phase system.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nRated voltage: AC 120V, 2‑pole configuration.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nSupported rated current range: 6A,10A,16A,20A,25A,32A,40A,50A,63A,80A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eLeakage protection performance\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe residual operating current is fixed at 30mA.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nIt trips rapidly when earth leakage reaches 30mA to prevent electric shock hazards.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nStandard trip response time: ≤40ms under rated residual current.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eApplication \u0026amp; installation compatibility\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eUnit is made as replacement part for US standard residential distribution panels.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nSuitable for 120V household lighting, socket and small‑power branch circuits.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nIt only applies to single‑phase 120V system, not for 240V main‑line direct use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eCore safety features\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eProvides human‑body electric shock protection and circuit leakage fire prevention.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nNo over‑current short‑circuit protection built‑in; match with MCB for full protection.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nWorking ambient temperature range:‑5℃ ~ +40℃ for indoor residential installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eQ1: Can this RCCB work on 240V US circuits?\u003c\/strong\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: No. This model is strictly rated for AC120V single‑phase residential panel, 240V input will damage the device.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eQ2: Does this breaker include overload \u0026amp; short‑circuit protection?\u003c\/strong\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes, It provide residual current RCCB. Also provides leakage protection and overload and short‑circuit safeguard.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eQ3: What does 30mA mean for end‑user safety?\u003c\/strong\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 30mA is the global household standard residual action value. It cuts power fast to reduce fatal electric‑shock risk for human contact.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eQ4: Which amp rating should I pick for home replacement?\u003c\/strong\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Match your original old RCCB rated current. Common household options:20A for general outlets,32‑63A for main branch circuit.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute Name\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003e120V 2P RCCB Residual Current Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole Number\u003c\/td\u003e\n\u003ctd\u003e2 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A,16A,20A,25A,32A,40A,50A,63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Operating Current\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Time\u003c\/td\u003e\n\u003ctd\u003e≤40ms (at rated residual current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eEarth‑leakage \/ Electric shock protection (With overload \u0026amp; short‑circuit protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eUS Residential Distribution Panel, 120V Single‑phase Household Branch Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5℃ ~ +40℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail mounting, replacement for existing RCCB unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGoogle Product Category\u003c\/td\u003e\n\u003ctd\u003e2271 (Circuit Breakers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"electrical center b2c","offers":[{"title":"Single RCCB 2P \/ 6A 30mA","offer_id":50516343259329,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 6A 30mA","price":40.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 10A 30mA","offer_id":50516343292097,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 10A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 16A 30mA","offer_id":50516343324865,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 16A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 20A 30mA","offer_id":50516343357633,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 20A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 25A 30mA","offer_id":50516343390401,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 25A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 32A 30mA","offer_id":50516343423169,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 32A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 40A 30mA","offer_id":50516343455937,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 40A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 50A 30mA","offer_id":50516343488705,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 50A 30mA","price":39.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 63A 30mA","offer_id":50516343521473,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 63A 30mA","price":41.0,"currency_code":"NZD","in_stock":true},{"title":"Single RCCB 2P \/ 80A 30mA","offer_id":50516343554241,"sku":"Residual Current Circuit Breaker 120V Single RCCB 2P \/ 80A 30mA","price":45.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 6A 30mA","offer_id":50516343587009,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 6A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 10A 30mA","offer_id":50516343619777,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 10A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 16A 30mA","offer_id":50516343652545,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 16A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 20A 30mA","offer_id":50516343685313,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 20A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 25A 30mA","offer_id":50516343718081,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 25A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 32A 30mA","offer_id":50516343750849,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 32A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 40A 30mA","offer_id":50516343783617,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 40A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 50A 30mA","offer_id":50516343816385,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 50A 30mA","price":43.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 63A 30mA","offer_id":50516343849153,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 63A 30mA","price":44.0,"currency_code":"NZD","in_stock":true},{"title":"RCCB + Mounting Din-rail \/ 80A 30mA","offer_id":50516343881921,"sku":"Residual Current Circuit Breaker 120V RCCB + Mounting Din-rail \/ 80A 30mA","price":48.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/120V.jpg?v=1787275347","url":"https:\/\/www.electric-b2c.com\/en-nz\/products\/120v-2p-rccb-residual-current-circuit-breaker-6a-80a-30ma-replacement-earth-leakage-breaker-for-us-residential-distribution-panel","provider":"electrical center b2c","version":"1.0","type":"link"}