SPECIFICATIONS

STC- 3028 Dual Digital Temperature Controller Hygrometer C/F Thermostat Two Relay Output AC 110V 220V DC 12V 24V 10A

Theory: Thermometer Hygrometer

Theory: Hygrometer

Style: Standing and Wall Hanging

Style: Embedded

Relay output: 10A/240VAC

Power supply: AC110-220V DC12V/24V

Power Type: Charger

Model Number: STC-3028

Max Measuring Temperature: 100°C - 119°C

Is Smart Device: NO

Housing material: gray ABS flame retardant plastic shell

Display Type: DIGITAL

Display Size: 1.9 Inches & Under

Cable Length: 1M

Accuracy: +-1C 0.1RH

STC- 3028 DATA SHEET DOWNLOAD

Feature:
Be able to control temperature and humidity at the same time.
Be able to connect with humidifier and dehumidifier equipment at the same time.
Be able to connect with refrigeration/ heating and humidifier/dehumidifier equipment at the same time.
Heating/Cooling function could be set separately for refrigeration and heating to protect temperature controller from violent change. Same as humidity Control.
Supporting Temp and Humidity Calibration
[Dual Display Window] Be able to display measured temperature/humidity and set temp/humidity at the same time
 
Specification:
 
Model: STC-3028
Input voltage: AC110~220V± 10%, DC24V, DC12V
Measuring temperature range: -0°~+110°
Measuring humidity range: 0%RH~+100%RH
Accuracy: ±1°, 0.1%RH
Relay output contact capacity: 10A/240VAC
Sensor length: 1m
 
Set startup temperature(humidity):
Press the "up" button once to display the starting temperature(humidity). Long press the "up" button for about 3 seconds,The required temperature(humidity) can be set by the up and down keys
 
Set stop temperature(humidity):
Press the "down"button once to display the stop temperature(humidity). Long press the button for about 3 seconds and the stop temperature(humidity) number flashes. The required temperature(humidity) can be set by the up and down keys
 
Temperature/humidity correction:
 
Press "up" and "down" button at the same time.

Care Instructions