{"product_id":"schneider-easy9b-residual-protection-device","title":"Schneider Electric EA9B Series 2P RCCB Type A 25\/40\/63A","description":"\u003ch3\u003eSchneider Electric EA9B Series 2P RCCB Residual Current Circuit Breaker 25A\/40A\/63A 30mA Type A DIN Rail Mount Leakage Protection Switch\u003c\/h3\u003e\n\u003ch4\u003eProduct Description\u003c\/h4\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eSchneider Electric EA9B series residual current circuit breakers (RCCBs) are integrated leakage protection devices designed to prevent electric shock and fire hazards caused by current leakage in low-voltage distribution systems. Equipped with 30mA high-sensitivity leakage protection and Class A protection characteristics, they are suitable for residential, commercial and industrial electrical equipment power supply systems.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Protection\u003c\/strong\u003e: 30mA rated residual operating current, Class A protection (compatible with AC\/ pulsating DC leakage), effectively protects against electric shock and insulation faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Performance\u003c\/strong\u003e: 2-pole configuration, rated breaking capacity up to 630A, ensuring rapid tripping and stable protection under overload and short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e: Flame-retardant insulating housing, high-conductivity copper contacts, and mechanical\/electrical life of 20,000\/10,000 cycles for long-term reliable use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient Installation\u003c\/strong\u003e: Standard 35mm DIN rail mount design with locking clip for quick, tool-free installation and secure fixation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Indication\u003c\/strong\u003e: Equipped with on\/off status indicator and contact position display for intuitive operation monitoring and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Application\u003c\/strong\u003e: Ideal for distribution boxes, control cabinets, residential circuits, industrial equipment, and household electrical safety protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDATA SHEET\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eITEM\u003c\/th\u003e\n\u003cth align=\"left\"\u003eVALUE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eBrand\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSeries\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eEA9B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eResidual Current Circuit Breaker (RCCB) \/ Leakage Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePoles (??????)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eRated Current\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e25A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eResidual Current\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eType A (AC + Pulsating DC leakage protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cspan class=\"container-mbkw8x math-inline\" data-custom-copy-text=\"\\(I_m = 630A\\)\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003em\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e=\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e630\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eInstantaneous (Selective: Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eFlame-retardant Insulating Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDIN Rail (35mm) with Locking Clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eManual Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMechanical\/Electrical Life\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e20,000 Cycles \/ 10,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eIndicator\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eOn\/Off Status Indicator + Contact Position Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eApplication Scenarios\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDistribution Box, Industrial Control Cabinet, Residential Circuit, Fire \u0026amp; Electric Shock Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSafety Certifications\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCompliant with IEC 61008, GB\/T 16917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eFunction\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eLeakage Protection, Overload Protection, Short-circuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFull Model \u0026amp; Parameter Table\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMPN \/ MODEL NO.\u003c\/th\u003e\n\u003cth\u003eItem No.\u003c\/th\u003e\n\u003cth\u003ePole\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eResidual Current\u003c\/th\u003e\n\u003cth\u003eLeakage Type\u003c\/th\u003e\n\u003cth\u003eBreaking Capacity\u003c\/th\u003e\n\u003cth\u003eModule Width\u003c\/th\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEA9B22530CA\u003c\/td\u003e\n\u003ctd\u003eEA9B22530CA\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEA9B24030CA\u003c\/td\u003e\n\u003ctd\u003eEA9B24030CA\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEA9B26330CA\u003c\/td\u003e\n\u003ctd\u003eEA9B26330CA\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"2P 25A\/30mA","offer_id":50360499994817,"sku":"EA9B 2P 25A\/30mA Type A RCCB","price":123.0,"currency_code":"AED","in_stock":true},{"title":"2P 40A\/30mA","offer_id":50360500027585,"sku":"EA9B 2P 40A\/30mA Type A RCCB","price":127.0,"currency_code":"AED","in_stock":true},{"title":"2P 63A\/30mA","offer_id":50360500060353,"sku":"EA9B 2P 63A\/30mA Type A RCCB","price":132.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/files\/imageye___-_imgi_8_O1CN01B2tnyI1jHaRtQWCww__910414523_jpg_q50_jpg.jpg?v=1776859470","url":"https:\/\/www.electric-b2c.com\/en-ae\/products\/schneider-easy9b-residual-protection-device","provider":"electrical center b2c","version":"1.0","type":"link"}