{"product_id":"pt100-temperature-sensor-platinum-resistance-pt1000-temperature-measuring","title":"PT100 temperature sensor, platinum resistance PT1000, temperature measuring range - 70~500 degrees Celsius, heraeus Germany\u0026#39;s","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003ePT100 temperature sensor, platinum resistance PT1000, temperature measuring range - 70~500 degrees Celsius, pt100 temperature sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsage\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003eIndustrial\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnit Type\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003epiece\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTheory\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003eTemperature Sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStyle\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003eEmbedded\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePackage Weight\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003e0.03kg (0.07lb.)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePackage Size\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003e16cm x 8cm x 5cm (6.30in x 3.15in x 1.97in)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003ePT1000\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMax Measuring Temperature\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003e120°C \u0026amp; Above\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003eDIGITAL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisplay Size\u003c\/span\u003e: \u003cspan style=\"color: #333;\"\u003e1.9 Inches \u0026amp; Under\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eM-series PRTDs are designed for large volume applications where long term stability,interchangeability andaccuracy over a large temperature range are vital. Typical applications are Automotive, White goods, HVAC,Energy management, Medical and Industrial equipment\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eNominal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eResistance R0\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eTolerance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eDIN EN 60751\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003e1996-07\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eTolerance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eDIN EN 60751\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003e2009-05\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cp align=\"center\"\u003e100 Ohm at 0°\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.15\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass 2B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cp align=\"center\"\u003e1000 Ohm at 0°\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.15\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass 2B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e                       \u003cspan\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1H1Rmaib.BuNjt_jDq6zOzpXaC.jpg\" alt=\"pt100-1\"\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003eThe measuring point for the nominal resistance is defined   at 8mm from the end of the sensor body.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e         70° to +500° (continuous operation)(temporary use to 550°possible)\u003c\/p\u003e\n\u003cp\u003e                                               Tolerance Class B\/D: -70° to +500°\u003c\/p\u003e\n\u003cp\u003e                                               Tolerance Class A: -50° to +300°\u003c\/p\u003e\n\u003cp\u003e                                               Tolerance Class C: 0° to +150°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e(\u003c\/strong\u003eTemperature range: \u003cspan\u003e -70~600°-----\u003c\/span\u003e\u003ca href=\"https:\/\/www.aliexpress.com\/store\/product\/Ultra-high-temperature-temperature-sensor-measuring-range-70-600-degrees-Celsius\/433051_32796689575.html?spm=2114.10010108.1000023.17.cSeJ8Z\"\u003e\u003cspan\u003eBuy here\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.aliexpress.com\/store\/product\/Ultra-high-temperature-temperature-sensor-measuring-range-70-600-degrees-Celsius\/433051_32796689575.html?spm=2114.10010108.1000023.17.cSeJ8Z\"\u003e \u003c\/a\u003e      -70~850°------\u003c\/span\u003e\u003ca href=\"https:\/\/www.aliexpress.com\/store\/product\/PRTD-ultra-high-temperature-type-PT100-temperature-sensor-temperature-measuring-range-70-850-degrees-Celsius\/433051_32794262973.html?spm=2114.12010612.0.0.aIOCor\"\u003e\u003cspan\u003eBuy here \u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e          -196~150°-----\u003c\/span\u003e\u003ca href=\"https:\/\/www.aliexpress.com\/store\/product\/Ultra-low-temperature-sensor-RTD-PT100-Measuring-range-196-150-degrees-Celsius\/433051_32797856726.html?spm=2114.12010612.0.0.0JYTth\"\u003e\u003cspan\u003eBuy here  \u003c\/span\u003e\u003c\/a\u003e\u003cstrong\u003e)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature coefficient:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e     TC = 3850 ppm\/K\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLeads:   \u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePt clad Ni- wire \u003c\/p\u003e\n\u003cp\u003e                 Recommended connection technology:\u003c\/p\u003e\n\u003cp\u003e                 Welding, Crimping and Brazing\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLead lengths (L):\u003c\/strong\u003e\u003cstrong\u003e      \u003c\/strong\u003eA\/B\/C:10mm ±1mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                      2B:5mm ± 0.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-term stability\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e        Max. R0 drift 0.04% after 1000h at 500°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e         At least 40g acceleration at 10 to 2000 Hz, depends on installation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShock resistance:\u003c\/strong\u003e           At least 100g acceleration with 8ms half sine wave, depends on installation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental conditions:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e  Unhoused for dry environments only\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e    ＞100 MΩ at 20°; ＞2 MΩ at 500°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf heating\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e         0.6 K\/mW at 0°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e        Water current (v= 0.4m\/s): t0.5 = 0.04s\u003c\/p\u003e\n\u003cp\u003e                                                                                     t0.9 = 0.12s\u003c\/p\u003e\n\u003cp\u003e                                    Air stream (v= 2m\/s): t0.5 = 2.2s\u003c\/p\u003e\n\u003cp\u003e                                                                          t0.9 = 7.0s\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring current\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e      100Ω: 0.3 to 1.0 mA\u003c\/p\u003e\n\u003cp\u003e                                           1000Ω: 0.1 to 0.3 mA (self heating has to be considered)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e  Other tolerances, values of resistance and wirelengths are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePT500B-series PRTDs are designed for large volume applications where long term stability, interchangeability andaccuracy over a large temperature range are vital. Typical applications are Automotive, White goods, HVAC,Energy management, Medical and Industrial equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eNominal\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eResistance R0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eTolerance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eDIN EN 60751\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e1996-07\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eTolerance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eDIN EN 60751\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e2009-05\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e500 Ohm at 0°\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eClass B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003eF 0.3\u003c\/p\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e               \u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1H1Rmaib.BuNjt_jDq6zOzpXaC.jpg\" alt=\"pt100-1\"\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003eThe measuring point for the nominal resistance is defined   at 8mm from the end of the sensor body.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature range:\u003c\/span\u003e          70° to +500° (continuous operation)(temporary use to 550°possible)\u003c\/p\u003e\n\u003cp\u003e                                               Tolerance Class B: -70° to +500°\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature coefficient:\u003c\/span\u003e      TC = 3850 ppm\/K\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLeads:    \u003c\/span\u003ePt clad Ni- wire \u003c\/p\u003e\n\u003cp\u003e                 Recommended connection technology:\u003c\/p\u003e\n\u003cp\u003e                 Welding, Crimping and Brazing\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLead lengths (L):     10mm ±1mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLong-term stability\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e        Max. R0 drift 0.04% after 1000h at 500°\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVibration resistance:\u003c\/span\u003e         At least 40g acceleration at 10 to 2000 Hz, depends on installation\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eShock resistance:\u003c\/span\u003e           At least 100g acceleration with 8ms half sine wave, depends on installation\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEnvironmental conditions: \u003c\/span\u003e  Unhoused for dry environments only\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInsulation resistance:\u003c\/span\u003e    ＞100 MΩ at 20°; ＞2 MΩ at 500°\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelf heating\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e         0.4 K\/mW at 0°\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e        Water current (v= 0.4m\/s): t0.5 = 0.05s\u003c\/p\u003e\n\u003cp\u003e                                                                                     t0.9 = 0.15s\u003c\/p\u003e\n\u003cp\u003e                                    Air stream (v= 2m\/s): t0.5 = 3.0s\u003c\/p\u003e\n\u003cp\u003e                                                                          t0.9 = 10.0s\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring current\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e       500Ω: 0.1 to 0.7 mA\u003c\/p\u003e","brand":"electrical center b2c","offers":[{"title":"PT1002B","offer_id":42031469396161,"sku":"14:350850#PT1002B","price":22.0,"currency_code":"AED","in_stock":true},{"title":"PT100B","offer_id":42031469428929,"sku":"14:350852#PT100B","price":23.0,"currency_code":"AED","in_stock":true},{"title":"PT100A","offer_id":42031469461697,"sku":"14:350853#PT100A","price":24.0,"currency_code":"AED","in_stock":true},{"title":"PT100C","offer_id":42031469494465,"sku":"14:10#PT100C","price":36.0,"currency_code":"AED","in_stock":false},{"title":"PT10002B","offer_id":42031469560001,"sku":"14:29#PT10002B","price":22.0,"currency_code":"AED","in_stock":true},{"title":"PT1000B","offer_id":42031469592769,"sku":"14:94#PT1000B","price":23.0,"currency_code":"AED","in_stock":true},{"title":"PT1000A","offer_id":42031469625537,"sku":"14:173#PT1000A","price":24.0,"currency_code":"AED","in_stock":true},{"title":"PT1000C","offer_id":42031469658305,"sku":"14:175#PT1000C","price":36.0,"currency_code":"AED","in_stock":false},{"title":"PT500 B","offer_id":42031469691073,"sku":"14:193#PT500 B","price":48.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/0872\/2881\/products\/pt100-temperature-sensor-platinum-resistance-pt1000-temperature-measuring-range-70-500-degrees-celsius-heraeus-germanyand39s-electrical-center-b2c.jpg?v=1718876581","url":"https:\/\/www.electric-b2c.com\/en-ae\/products\/pt100-temperature-sensor-platinum-resistance-pt1000-temperature-measuring","provider":"electrical center b2c","version":"1.0","type":"link"}