Ampere
Built-in Accessories

Shunt Trip Breaker TREF4-250 Earth Leakage Circuit Breaker ELCB 250F/4P 100A-250A

ELCB TREM Series

A Shunt trip breakers are often used in concert with sprinkler and other fire suppression systems that can potentially short-circuit electrical appliances. The shunt breaker is connected to the fire detector or alarm, so that when the alarm is triggered, the breaker is automatically tripped, cutting the power to any computers, electronic locks or other electrical equipment before the sprinklers can soak them in water.


Mould Case Circuit Breaker with Earth Leakage Protection


Standard
TRM series circuit breaker

 and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist 

4 pole elcb price,elcb for 3 phase,elcb three phase,elcb 100 amp 4 pole,shunt trip breaker

CLASSIFICATION:
ACCORDING TO THE POLES:                                        2-POLES, 3-POLES
ACCORDING TO THE BREAKING CAPACITY:                       S-TYPE, H-TYPE
ACCORDING TO THE RATED CURRENT:                             FIX TYPE, ADJUSTABLE TYPE(08IN-1.0IN)
ACCORDING TO THE TRIP ACTION TIME:                           FIX TYPE, ADJUSTABLE TYPE(0.1S/0.3S/0.5S OR 0.45S/1.0S/2.0S)
ACCORDING TO THE RATED RESIDUAL CURRENT:                 FIX TYPE, ADJUSTABLE TYPE(30MA/100MA/300MA/500MA)

3 pole earth leakage circuit breaker,3 pole elcb,3p elcb,elcb 200 amp,shunt trip breaker


ELCB
Technical data table:
Ampere frame size TREF4(250A)
Breaking capacity code S H
Product code and poles 3P 4P 3P 4P
TREF4-S3 TREF4-S4 TREF4-H3 TREF4-H4
Protective function Over load & Short circuit & Ground fault
Rated current, In(A) 100, 125, 160, 180, 200, 225, 250
Rated residual current Operating, IΔn(mA) 30, 50, 100, 200, 300, 500
Non-operating, IΔno(mA) 15, 25, 50, 100, 150, 250
Adjustable part Rated current setting(0.8In-1.0In)
Lockup device for operating handle
Residual current, IΔn 30mA/100mA/300mA/500mA
Trip action time 0.1s/0.3s/0.5s
Rated operational voltage, Ue(V), AC 50/60 Hz 240/415
Rated insulation voltage, Ui(V) 1000
Rated impulse withstand voltage, Uimp(kV) 8
Residual current off-time at IΔn ,Sec (s) 0.1
Standard Conformity with IEC/EN 60947-2
Rated frequency(Hz) 50/60
Rated short-circuit breaking capacity, Icu(kA)
AC 240V 50 65
415V 37 50
Ics=% * Icu 100%
Mechanical life(circle) 7000
Electrical life(circle) 1000
Dimension:
Length*Width*Height
2-poles -
3-poles 165*105*60
4-poles 165*140*60
Built-in accessory:
modular mccb
Built-out accessory: